IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2020 · 41 citations · 23 references
MedicineBiomedical EngineeringRadiologyDiagnostic ImagingUltrasonographyUltrasoundBeamformingDiagnostic UltrasonographyTransducer TechnologyUltrasonicsUltrasound ImagingUltrasound PhysicsDelay-and-sum BeamformingFlexible TransducersLinear Array TransducersShape EstimationTransducersUltrasonic Transducer ArraysUltrasonic TransducersUltrasound Image Reconstruction
A flexible ultrasonic array transducer able to be attached to the body has the potential to achieve long-term continuous unconstrained ultrasound (US) imaging. However, the quality of reconstructed US images is affected by the accuracy of the estimated array shape because the array shape is primitive for time-delay calculation in delay-and-sum beamforming. In this study, we propose an algorithm for estimating the array shape only from the backscattered US signal without using any external device. The proposed algorithm is based on the assumption that beam-summed images reconstructed using an array shape estimated at higher accuracy would have smaller entropy. The array shape is estimated by searching for the shape with minimal entropy, which was used as the index of the beam-summed image quality. Simulation experiments and phantom experiments were used to evaluate the proposed algorithm. In the simulation experiments, three different array shapes with 2.0 MHz, 20 elements, and 0.8-mm pitch transducers were estimated. In the phantom experiments, the array shapes of commercially available linear, convex, and concave transducers were estimated. The results showed that the proposed algorithm can estimate the correct array shape with an average element position error of less than one-eighth of the wavelength of the transmitted signals. These results indicate that the proposed algorithm can achieve sufficiently accurate shape estimation and has the potential to enable clear US imaging with flexible array transducers.
23
Adam: A Method for Stochastic Optimization
Diederik P. Kingma, Jimmy Ba · UvA-DARE (University of Amsterdam) · 2014 · 84.8K citations · Full text
Image quality assessment: from error visibility to structural similarity
Zhou Wang, Alan C. Bovik, Hamid R. Sheikh et al. · IEEE Transactions on Image Processing · 2004 · 56K citations
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Chonghe Wang, Xiaoshi Li, Hongjie Hu et al. · Nature Biomedical Engineering · 2018 · 878 citations · Full text
Medicine, Physics, Physiology +14