TL;DR

Bioresorbable passive resonance sensors based on LC circuits offer a promising, battery‑free implant technology that is simple, wirelessly readable, and ultimately metabolizable by the body. This study evaluates the fabrication and performance of diverse LC‑based sensors to provide a comprehensive overview of material choices and manufacturing techniques. The investigation examines sensor components such as bioresorbable polymer and bioactive glass substrates, dissolvable metallic conductors, and atomic‑layer‑deposited water‑barrier films on polymeric substrates. The authors fabricated a polymer‑based pressure sensor that remained responsive for 10 days in aqueous media, a first wirelessly readable bioactive‑glass resonance sensor for permittivity monitoring, and a solenoidal‑coil compression sensor integrated into a polymeric bone‑fixation screw, establishing a reference for future orthopedic applications.

Abstract

Bioresorbable passive resonance sensors based on inductor–capacitor (LC) circuits provide an auspicious sensing technology for temporary battery-free implant applications due to their simplicity, wireless readout, and the ability to be eventually metabolized by the body. In this study, the fabrication and performance of various LC circuit-based sensors are investigated to provide a comprehensive view on different material options and fabrication methods. The study is divided into sections that address different sensor constituents, including bioresorbable polymer and bioactive glass substrates, dissolvable metallic conductors, and atomic layer deposited (ALD) water barrier films on polymeric substrates. The manufactured devices included a polymer-based pressure sensor that remained pressure responsive for 10 days in aqueous conditions, the first wirelessly readable bioactive glass-based resonance sensor for monitoring the complex permittivity of its surroundings, and a solenoidal coil-based compression sensor built onto a polymeric bone fixation screw. The findings together with the envisioned orthopedic applications provide a reference point for future studies related to bioresorbable passive resonance sensors.

References

60