Journal of Cardiovascular Electrophysiology · 2020 · 85 citations · 24 references
MedicineCardiologyCardiothoracic SurgeryClinical CardiologyInterventional CardiologyCardiac PacingElectrocardiographyHeart FailureB-type Natriuretic PeptidesBiventricular PacingCardiac Systolic FunctionInterventricular SeptumIntracardiac PacingLeft Bundle Branch Area PacingQrs DurationQrs Prolongation
BACKGROUND: Left bundle branch area pacing (LBBAP) was reported to improve cardiac function by correcting complete left bundle branch block (CLBBB). Our study aimed to compare the efficacy of LBBAP and biventricular pacing (BIVP) in heart failure patients with CLBBB. METHODS: Ten patients prospectively underwent LBBAP (LBB-CRT group) and 30 patients received BIVP (BIV-CRT group) were matched using propensity score matching. LBBAP was achieved by the trans-interventricular septum method. Echocardiography, electrocardiogram, NYHA classification, and blood B-type natriuretic peptide concentration were evaluated at preimplantation and at 6-month follow up. CRT response was defined as at least 15% decrease in left ventricular end-systolic volume. RESULTS: In the LBB-CRT group, CLBBB were successfully corrected by LBBAP with no complications. QRS duration (QRSd) significantly decreased after implantation in both groups, and the decrease of QRSd in the LBB-CRT group was significantly greater than that in the BIV-CRT group (60.80 ± 20.09 vs. 33.00 ± 21.48 ms, p = .0009). The echocardiographic measurements including left ventricular end-diastolic diameter, left ventricular end-systolic diameter, and left ventricular ejection fraction significantly improved after 6 months in both groups. The response rate was significantly higher in LBB-CRT group than BIV-CRT group (100.00% vs. 63.33%, p = .038). The percentage of patients in New York Heart Association classification Grades I and II was significantly higher in the LBB-CRT group compared with that in the BIV-CRT group (median 1.5 vs. 2.0, p = .029) at 6-month follow-up. CONCLUSIONS: It is effective and safe to correct CLBBB with LBBAP in heart failure patients. Compared with BIVP, LBBAP can better optimize electrical synchrony and improve cardiac function.
24
Cardiac Resynchronization in Chronic Heart Failure
William T. Abraham, Westby G. Fisher, Andrew L. Smith et al. · New England Journal of Medicine · 2002 · 4.6K citations · Full text
CARDIAC RESYNCHRONIZATION IN CHRONIC HEART FAILURE
W Illiam T. A Braham, W Estby G. F Isher, L. S Mith et al. · 2002 · 3.8K citations
Cardiac-Resynchronization Therapy for Mild-to-Moderate Heart Failure
Anthony Tang, George A. Wells, Mario Talajic et al. · New England Journal of Medicine · 2010 · 1.9K citations
Cecilia Linde, William T. Abraham, Michael R. Gold et al. · Journal of the American College of Cardiology · 2008 · 1.3K citations · Full text