Skeletal Radiology · 2020 · 18 citations · 32 references
MedicinePediatricsRadiologyDiagnostic ImagingDiagnostic RadiologyPediatric RadiologyComputed TomographyImage QualityImage Quality AssessmentPediatric ImagingRadiographic ImagingTrauma ImagingBeam HardeningExtremity Trauma ImagingImage Noise AssessmentRadiation Dose EstimationRadiographic Image QualitySignal-to-noise AssessmentSignal-to-noise RatioX-ray Beam Hardening
Abstract Introduction Novel dedicated extremity cone beam computed tomography (CBCT) devices, recently introduced to the market, raised attention as a possible alternative in advanced diagnostic pediatric trauma imaging, today usually performed by multidetector computed tomography (MDCT). This work aimed to compare image quality and radiation dose of CBCT and MDCT. Materials and methods Fifty-four CBCT-MDCT examination pairs, containing nine MDCTs acquired in parallel prospectively and 45 MDCTs matched in retrospect, were included in this study. Image quality was analyzed semi-objectively by measuring noise, contrast-to-noise ratio (CNR), and signal-to-noise ratios (SNR) and subjectively by performing image impression ratings. CT dose records were readout. Results Image noise was significantly lower in CBCT compared with MDCT, both semi-objectively and subjectively (both p < 0.001). CNR and SNRs were also in favor of CBCT, though CBCT examinations exhibited significantly more beam hardening artifacts that diminished the advantages of the superior semi-objective image quality. These artifacts were believed to occur more often in children due to numerous bone-cartilage transitions in open growth plates and may have led to a better subjective diagnostic certainty rating ( p = 0.001). Motion artifacts were infrequently, but exclusively observed in CBCT. CT dose index (CTDI vol ) was substantially lower in CBCT ( p < 0.001). Conclusion Dedicated extremity CBCT could be an alternative low-dose modality in the diagnostic pathway of pediatric fractures. At lower doses compared with MDCT and commonly affected by beam hardening artifacts, semi-objective CBCT image quality parameters were generally better than in MDCT.
32
Fiji: an open-source platform for biological-image analysis
Johannes Schindelin, Ignacio Arganda‐Carreras, Erwin Frise et al. · Nature Methods · 2012 · 70.9K citations
Radiation Exposure from Musculoskeletal Computerized Tomographic Scans
Debdut Biswas, Jesse E. Bible, Michael Bohan et al. · Journal of Bone and Joint Surgery · 2009 · 437 citations
Dedicated Cone-Beam CT System for Extremity Imaging
John A. Carrino, Abdullah Al Muhit, Wojciech Zbijewski et al. · Radiology · 2013 · 222 citations