EngineeringArchitectural EngineeringAcousticsSensorsVentilationGas Exchange AssessmentGas SensorsVentilation InstrumentationVentilation SystemsAcoustic Wave MeasurementGas Sensor Response TimeNatural Ventilation EffectsPhotoacoustic Gas SensorsQuantum Cascade LasersSensor Response TimeVentilation Rate AssessmentVentilation Sensors
Abstract We reported the development of a quartz-enhanced photoacoustic sulfur hexafluoride (SF 6 ) sensor for ventilation studies using a continuous-wave distributed-feedback quantum cascade laser (QCL) at 10.5 µm. The SF 6 sensor was developed by detecting the gas-absorption induced acoustic wave using a tiny quartz tuning fork that is enclosed in a gas cell with a sample volume of 2.5 ml. By locking the QCL wavelength at the absorption peak of SF 6 , we obtained a recording time interval of 0.4 s and a detection limit of 4.6 ppb. The sensor response time (t 90 ) was found to be 2.8 s at a flow rate of 550 ml min −1 . The sensor was then implemented in measuring air exchange rates in a laboratory room using the standard tracer gas concentration decay method. Our measurements are in good agreement with a commercial analyzer when studying two typical passive ventilation scenarios of infiltration and natural ventilation. Additionally, the developed photoacoustic gas sensor is fast enough to capture the transient variations of the SF 6 concentration during natural ventilation. This study provides a promising method of studying transient contaminant transport that remains a major challenge in air quality research.
25
Quartz-enhanced photoacoustic spectroscopy
A.A. Kosterev, Yu. A. Bakhirkin, R. F. Curl et al. · Optics Letters · 2002 · 776 citations