European Radiology · 2020 · 20 citations · 22 references
MedicineCardiologyRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic RadiologyAortic ImagingCardiac ImagingCardiovascular ImagingMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsVascular ImagingAortic Imaging MeasurementsAscending Aorta ImagingBalanced Steady-state Free PrecessionContrast-enhanced AngiographyContrast-enhanced Magnetic Resonance AngiographyContrast-enhanced Thoracic ImagingImage Acquisition QualityMagnetic Resonance Angiography
OBJECTIVES: Assessment of thoracic aortic dimensions with non-ECG-triggered contrast-enhanced magnetic resonance angiography (CE-MRA) is accompanied with motion artefacts and requires gadolinium. To avoid both motion artefacts and gadolinium administration, we evaluated the similarity and reproducibility of dimensions measured on ECG-triggered, balanced steady-state free precession (SSFP) MRA as alternative to CE-MRA. METHODS: All patients, with varying medical conditions, referred for thoracic aortic examination between September 2016 and March 2018, who underwent non-ECG-triggered CE-MRA and SSFP-MRA (1.5 T) were retrospectively included (n = 30). Aortic dimensions were measured after double-oblique multiplanar reconstruction by two observers at nine landmarks predefined by literature guidelines. Image quality was scored at the sinus of Valsalva, mid-ascending aorta and mid-descending aorta by semi-automatically assessing the vessel sharpness. RESULTS: Aortic dimensions showed high agreement between non-ECG-triggered CE-MRA and SSFP-MRA (r = 0.99, p < 0.05) without overestimation or underestimation of aortic dimensions in SSFP-MRA (mean difference, 0.1 mm; limits of agreement, - 1.9 mm and 1.9 mm). Intra- and inter-observer variabilities were significantly smaller with SSFP-MRA for the sinus of Valsalva and sinotubular junction. Image quality of the sinus of Valsalva was significantly better with SSFP-MRA, as fewer images were of impaired quality (3/30) than in CE-MRA (21/30). Reproducibility of dimensions was significantly better in images scored as good quality compared to impaired quality in both sequences. CONCLUSIONS: Thoracic aortic dimensions measured on SSFP-MRA and non-ECG-triggered CE-MRA were similar. As expected, SSFP-MRA showed better reproducibility close to the aortic root because of lesser motion artefacts, making it a feasible non-contrast imaging alternative. KEY POINTS: • SSFP-MRA provides similar dimensions as non-ECG-triggered CE-MRA. • Intra- and inter-observer reproducibilities improve for the sinus of Valsalva and sinotubular junction with SSFP-MRA. • ECG-triggered SSFP-MRA shows better image quality for landmarks close to the aortic root in the absence of cardiac motion.
22
2014 ESC Guidelines on the diagnosis and treatment of aortic diseases
Raimund Erbel, Victor Aboyans, Cathérine Boileau et al. · European Heart Journal · 2014 · 4.4K citations · Full text
Medicine, Cardiology, Surgery +14
Jeanette Schulz‐Menger, David A. Bluemke, Jens Bremerich et al. · Journal of Cardiovascular Magnetic Resonance · 2013 · 1.5K citations · Full text
Medicine, Cardiology, Radiology +16