Radiation Oncology · 2020 · 109 citations · 48 references
MedicineRadiation OncologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyImage-guided TherapyMagnetic Resonance ImagingMedical Image AnalysisMedical ImagingProstate ImagingVolume SegmentationComputed Tomography Based ContouringContouringConvolutional Neural Network SegmentationConvolutional Neural NetworksDeep Learning In RadiologyMagnetic Resonance Imaging-based DelineationProstate ContouringSpoiled Gradient Echo Imaging
Abstract Background Structure delineation is a necessary, yet time-consuming manual procedure in radiotherapy. Recently, convolutional neural networks have been proposed to speed-up and automatise this procedure, obtaining promising results. With the advent of magnetic resonance imaging (MRI)-guided radiotherapy, MR-based segmentation is becoming increasingly relevant. However, the majority of the studies investigated automatic contouring based on computed tomography (CT). Purpose In this study, we investigate the feasibility of clinical use of deep learning-based automatic OARs delineation on MRI. Materials and methods We included 150 patients diagnosed with prostate cancer who underwent MR-only radiotherapy. A three-dimensional (3D) T1-weighted dual spoiled gradient-recalled echo sequence was acquired with 3T MRI for the generation of the synthetic-CT. The first 48 patients were included in a feasibility study training two 3D convolutional networks called DeepMedic and dense V-net (dV-net) to segment bladder, rectum and femurs. A research version of an atlas-based software was considered for comparison. Dice similarity coefficient, 95% Hausdorff distances (HD 95 ), and mean distances were calculated against clinical delineations. For eight patients, an expert RTT scored the quality of the contouring for all the three methods. A choice among the three approaches was made, and the chosen approach was retrained on 97 patients and implemented for automatic use in the clinical workflow. For the successive 53 patients, Dice, HD 95 and mean distances were calculated against the clinically used delineations. Results DeepMedic, dV-net and the atlas-based software generated contours in 60 s, 4 s and 10-15 min, respectively. Performances were higher for both the networks compared to the atlas-based software. The qualitative analysis demonstrated that delineation from DeepMedic required fewer adaptations, followed by dV-net and the atlas-based software. DeepMedic was clinically implemented. After retraining DeepMedic and testing on the successive patients, the performances slightly improved. Conclusion High conformality for OARs delineation was achieved with two in-house trained networks, obtaining a significant speed-up of the delineation procedure. Comparison of different approaches has been performed leading to the succesful adoption of one of the neural networks, DeepMedic, in the clinical workflow. DeepMedic maintained in a clinical setting the accuracy obtained in the feasibility study.
48
Simple proton spectroscopic imaging.
W. Thomas Dixon · Radiology · 1984 · 2.3K citations
Violin Plots: A Box Plot-Density Trace Synergism
Jerry L. Hintze, Ray D. Nelson · The American Statistician · 1998 · 1.6K citations
Automatic Multi-Organ Segmentation on Abdominal CT With Dense V-Networks
Eli Gibson, Francesco Giganti, Yipeng Hu et al. · IEEE Transactions on Medical Imaging · 2018 · 715 citations
Hiram A. Gay, H. Joseph Barthold, Elizabeth O’Meara et al. · International Journal of Radiation Oncology*Biology*Physics · 2012 · 537 citations · Full text