EJNMMI Research · 2020 · 69 citations · 20 references
MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyAttenuation CorrectionComputed TomographyDeep LearningMedical ImagingMultimodal ImagingPositron Emission TomographyAttenuation Map GenerationComputed Tomography AcquisitionDeep Learning In RadiologyGenerative Adversarial NetworksPet AcquisitionPet Attenuation CorrectionPet-computed TomographyWhole-body Pet Imaging
Abstract Background Attenuation correction (AC) of PET data is usually performed using a second imaging for the generation of attenuation maps. In certain situations however—when CT- or MR-derived attenuation maps are corrupted or CT acquisition solely for the purpose of AC shall be avoided—it would be of value to have the possibility of obtaining attenuation maps only based on PET information. The purpose of this study was to thus develop, implement, and evaluate a deep learning-based method for whole body [ 18 F]FDG-PET AC which is independent of other imaging modalities for acquiring the attenuation map. Methods The proposed method is investigated on whole body [ 18 F]FDG-PET data using a Generative Adversarial Networks (GAN) deep learning framework. It is trained to generate pseudo CT images (CT GAN ) based on paired training data of non-attenuation corrected PET data (PET NAC ) and corresponding CT data. Generated pseudo CTs are then used for subsequent PET AC. One hundred data sets of whole body PET NAC and corresponding CT were used for training. Twenty-five PET/CT examinations were used as test data sets (not included in training). On these test data sets, AC of PET was performed using the acquired CT as well as CT GAN resulting in the corresponding PET data sets PET AC and PET GAN . CT GAN and PET GAN were evaluated qualitatively by visual inspection and by visual analysis of color-coded difference maps. Quantitative analysis was performed by comparison of organ and lesion SUVs between PET AC and PET GAN . Results Qualitative analysis revealed no major SUV deviations on PET GAN for most anatomic regions; visually detectable deviations were mainly observed along the diaphragm and the lung border. Quantitative analysis revealed mean percent deviations of SUVs on PET GAN of − 0.8 ± 8.6% over all organs (range [− 30.7%, + 27.1%]). Mean lesion SUVs showed a mean deviation of 0.9 ± 9.2% (range [− 19.6%, + 29.2%]). Conclusion Independent AC of whole body [ 18 F]FDG-PET is feasible using the proposed deep learning approach yielding satisfactory PET quantification accuracy. Further clinical validation is necessary prior to implementation in clinical routine applications.
20
Attenuation correction for a combined 3D PET/CT scanner
Paul E. Kinahan, D.W. Townsend, Thomas Beyer et al. · Medical Physics · 1998 · 933 citations
3D conditional generative adversarial networks for high-quality PET image estimation at low dose
Yan Wang, Biting Yu, Lei Wang et al. · NeuroImage · 2018 · 457 citations · Full text
Corinna Bürger, Gerhard W. Goerres, S. Schoenes et al. · European Journal of Nuclear Medicine and Molecular Imaging · 2002 · 425 citations