Analytical Chemistry · 2020 · 312 citations · 38 references
Life SciencesBiochemistryAnalytical ChemistryMass Spectrometric AnalysisMetabolomicsMass SpectrometryMass Spectrometry-based MetabolomicsMetabolite IdentificationMetabolite ProfilingMetabolite QuantificationUntargeted MetabolomicsAcquisition TechniquesChromatography-based MetabolomicsData-dependent AcquisitionData-independent AcquisitionLiquid Chromatography-mass SpectrometryLiquid Chromatography-mass Spectrometry AnalysisMass Spectrometry-based Metabolite ProfilingReversed-phase Liquid Chromatography
Full-scan, data-dependent acquisition (DDA), and data-independent acquisition (DIA) are the three common data acquisition modes in high resolution mass spectrometry-based untargeted metabolomics. It is an important yet underrated research topic on which acquisition mode is more suitable for a given untargeted metabolomics application. In this work, we compared the three data acquisition techniques using a standard mixture of 134 endogenous metabolites and a human urine sample. Both hydrophilic interaction and reversed-phase liquid chromatographic separation along with positive and negative ionization modes were tested. Both the standard mixture and urine sample generated consistent results. Full-scan mode is able to capture the largest number of metabolic features, followed by DIA and DDA (53.7% and 64.8% respective features fewer on average in urine than full-scan). Comparing the MS2 spectra in DIA and DDA, spectra quality is higher in DDA with average dot product score 83.1% higher than DIA in Urine(H), and the number of MS2 spectra (spectra quantity) is larger in DIA (on average 97.8% more than DDA in urine). Moreover, a comparison of relative standard deviation distribution between modes shows consistency in the quantitative precision, with the exception of DDA showing a minor disadvantage (on average 19.8% and 26.8% fewer features in urine with RSD < 5% than full-scan and DIA). In terms of data preprocessing convenience, full-scan and DDA data can be processed by well-established software. In contrast, several bioinformatic issues remain to be addressed in processing DIA data and the development of more effective computational programs is highly demanded.
38
MS-DIAL: data-independent MS/MS deconvolution for comprehensive metabolome analysis
Hiroshi Tsugawa, Tomáš Čajka, Tobias Kind et al. · Nature Methods · 2015 · 3.4K citations · Full text
Life Sciences, Biochemistry, Mass Spectrometric Analysis +13
MetaboAnalyst 3.0—making metabolomics more meaningful
Jianguo Xia, Igor Sinelnikov, David S. Wishart · Nucleic Acids Research · 2015 · 2.7K citations · Full text