Journal of Cataract & Refractive Surgery · 2020 · 29 citations · 33 references
MedicineOphthalmologySurgeryBiomedical OpticsOphthalmic SurgeryRefractive SurgeryCorneal OpticsLaser In Situ KeratomileusisOcular BiometryPostoperative Refractive OutcomesPreoperative Refractive EvaluationRefractive Error AssessmentBiometric FormulaeError PredictionLens Exchange SurgeryMean Squared ErrorPostoperative RefractionRefractive Cataract SurgerySpherical Equivalent RefractionTarget Refraction Accuracy
BACKGROUND: To evaluate IOL calculation formulas provided by an online calculation tool from the ASCRS for an extended depth-of-focus (EDOF) IOL after previous myopic laser in situ keratomileusis (LASIK). SETTING: Department of Ophthalmology, Goethe University, Frankfurt, Germany. DESIGN: Retrospective consecutive case series. METHODS: Patients who underwent cataract surgery or refractive lens exchange with implantation of a diffractive EDOF IOL and who had a history of myopic LASIK were included. Biometry, refractive data regarding the LASIK procedure, target refraction, and postoperative refraction were collected. Mean prediction error, mean absolute error (MAE), and the number of eyes within ±0.5 diopters (D), ±1.0 D, ±1.5 D, and ±2.0 D were calculated with the following formulas from the ASCRS calculator: Shammas, Haigis-L, Barrett True-K, Barrett No History, Masket, modified Masket, and the average of all formulas (average). RESULTS: Twenty-five eyes matched the inclusion criteria. Mean spherical equivalent (SE) was -0.81 ± 0.69 D; the mean pre-LASIK SE was -6.4 ± 3.63 D. The formulas ranked by MAE were Shammas (0.7 ± 0.75 D), Haigis-L (0.72 ± 0.57 D), average (0.79 ± 0.8 D), Barrett True-K (1.14 ± 0.89 D), modified Masket (1.4 ± 1.15 D), Barrett No History (1.45 ± 0.7D ), and Masket (1.64 ± 1.27 D). The formulas with the most eyes within ±0.5 D were average (52%), Shammas (48%), and Haigis-L (44%) formulas. CONCLUSIONS: Calculation of IOLs in eyes with a history of refractive surgery remains a challenge. In this study, the Shammas and Haigis-L formulas performed best regarding MAE and percentage of eyes within ±0.5 D; however, the average of all formulas delivered reasonable results.
33
Petros Aristodemou, Nathaniel E. Knox Cartwright, J M Sparrow et al. · Journal of Cataract & Refractive Surgery · 2010 · 329 citations
Medicine, Ophthalmology, Surgery +17
Intraocular lens power formula accuracy: Comparison of 7 formulas
Jack X. Kane, Anton Van Heerden, Alp Atik et al. · Journal of Cataract & Refractive Surgery · 2016 · 325 citations
Medicine, Ophthalmology, Surgery +17
Benchmark standards for refractive outcomes after NHS cataract surgery
Richard Gale, Manuel Saldaña, Robert L. Johnston et al. · Eye · 2007 · 265 citations
Medicine, Ophthalmology, Surgery +16