Analytical Chemistry · 2020 · 17 citations · 31 references
EngineeringBioengineeringMaterials ScienceBiosensorsOptical MaterialsSensorsHydrogelsOptical BiosensingOptical BiosensorsOptical PolymersOptical SensorsPolymeric BiomaterialsBiosensingBiosensing PlatformsBiosensor MaterialsOptical TransparencyRefractive Index BiosensingRefractive Index SensingWaveguide BiosensorsWaveguide-based Biosensing
The metal-clad leaky waveguide (MCLW) is an optical biosensor consisting of a metal layer and a low index waveguide layer on a glass substrate. This label-free sensor measures refractive index (RI) changes within the waveguide layer. This work shows the development and optimization of acrylate based-hydrogel as the waveguide layer formed from PEG diacrylate (PEGDA, Mn 700), PEG methyl ether acrylate (PEGMEA, Mn 480), and acrylate-PEG2000-NHS fabricated on a substrate coated with 9.5 nm of titanium. The acrylate-based hydrogel is a synthetic polymer, so properties such as optical transparency, porosity, and hydrogel functionalization by a well-controlled reactive group can be tailored for immobilization of the bioreceptor within the hydrogel matrix. The waveguide sensor demonstrated an equal response to solutions of identical RI containing small (glycerol) and large (bovine serum albumin; BSA) analyte molecules, indicating that the hydrogel waveguide film is highly porous to both sizes of molecule, thus potentially allowing penetration of a range of analytes within the porous matrix. The final optimized MCLW chip was formed from a total hydrogel concentration of 40% v/v of PEGMEA–PEGDA (Mn 700), functionalized with 2.5% v/v of acrylate-PEG2000-NHS. The sensor generated a single-moded waveguide signal with a RI sensitivity of 128.61 ± 0.15° RIU–1 and limit of detection obtained at 2.2 × 10–6 RIU with excellent signal-to-noise ratio for the glycerol detection. The sensor demonstrated RI detection by monitoring changes in the out-coupled angle resulting from successful binding of d-biotin to streptavidin immobilized on functionalized acrylate hydrogel, generating a binding signal of (12.379 ± 0.452) × 10–3°.
31
Light Waves in Thin Films and Integrated Optics
P. K. Tien · Applied Optics · 1971 · 1.1K citations
Light-guiding hydrogels for cell-based sensing and optogenetic synthesis in vivo
Myunghwan Choi, Jin Woo Choi, Seonghoon Kim et al. · Nature Photonics · 2013 · 377 citations · Full text
pH- and Temperature-Sensitive Hydrogel Nanoparticles with Dual Photoluminescence for Bioprobes
Yüe Zhao, Ce Shi, Xudong Yang et al. · ACS Nano · 2016 · 242 citations