IEEE Transactions on Industrial Electronics · 2020 · 29 citations · 36 references
EngineeringElectrical EngineeringElectric MachinesMachine DesignPower ElectronicsElectromagnetic Torque ProductionMachine TestingMachine WindingsMagnetic Circuit AnalysisSynchronous MachinesArmature WindingsFault Tolerance PerformanceFault Tolerant OperationStator WindingsTopology DesignTorqueTorque Density OptimizationTorque Output
This article proposes a novel doubly fed flux reversal machine (DF-FRM) with two sets of armature windings wound on both stator and rotor teeth. The proposed DF-FRM can provide much higher torque density than conventional FRM due to better utilization of rotor space. Moreover, the DF-FRM exhibits higher fault tolerance and it can still offer almost the desired output torque of FRM during fault operation, albeit one set of armature windings is malfunctioning. The machine topology as well as operation principles of a 12-stator-slot/14-rotor-slot DF-FRM is introduced and explained. Furthermore, the electromagnetic performances of FRM and DF-FRM with optimized structure aiming at maximum torque density are analyzed and compared using finite element (FE) method. The results show that DF-FRM can yield 60% higher torque density than the conventional FRM. Finally, a prototype is manufactured and tested to validate the FE results.
36
Overview of Stator-Permanent Magnet Brushless Machines
Ming Cheng, Wei Hua, Jianzhong Zhang et al. · IEEE Transactions on Industrial Electronics · 2011 · 814 citations