Non‐invasive measurement of retinal permeability in a diabetic rat model

Claire Allen, Naseeb Kaur Malhi, Jacqueline L. Whatmore, David O. Bates, Kenton P. Arkill

Microcirculation · 2020 · 17 citations · 30 references

DOIFull text

Open access

Concepts

Abstract

OBJECTIVE: The gold standard for measuring blood-retinal barrier permeability is the Evans blue assay. However, this technique has limitations in vivo, including non-specific tissue binding and toxicity. This study describes a non-toxic, high-throughput, and cost-effective alternative technique that minimizes animal usage. METHODS: Sodium fluorescein fundus angiography was performed in non-diabetic and diabetic Brown Norway rats on days 0, 7, 14, 21, and 28. Sodium fluorescein intensity in the retinal interstitium and a main retinal vessel were measured over time. The intensity gradients were used to quantify retinal vascular permeability. Post-study eyes were fixed, dissected, and stained (isolectin B4) to measure required parameters for permeability quantification including total vessel length per retinal volume, radius, and thickness. RESULTS: In the non-diabetic cohort retinal permeability remained constant over the 28-day study period. However, in the diabetic cohort there was a significant and progressive increase in retinal permeability from days 14-28 (P < .01, P < .001, P < .0001). CONCLUSIONS: This novel imaging methodology in combination with mathematical quantification allows retinal permeability to be non-invasively and accurately measured at multiple time points in the same animal. In addition, this technique is a non-toxic, rapid, sensitive, and cost-effective alternative to the Evans blue assay.

References

30