Clinical Cancer Research · 2020 · 109 citations · 32 references
MedicineOncologyBiomedical ImagingGastrointestinal OncologyMolecular ImagingColorectal CancerFluorescence ImagingGastrointestinal Cancer SurgeryMolecular Imaging In OncologyNear-infrared ImagingTumor ImagingFluorescence Contrast AgentsIntraoperative VisualizationNear-infrared Fluorescence ImagingNear-infrared Imaging AgentsNear-infrared ProbesNeoadjuvant ChemoradiotherapyPrimary Tumor AssessmentSurgical Downstaging
PURPOSE: Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the standard treatment modality for locally advanced rectal cancer, where subsequent downstaging can make identification of the primary tumor more challenging during surgery. Near-infrared (NIR) fluorescence imaging can aid surgeons by providing real-time visualization of tumors and vital structures during surgery. EXPERIMENTAL DESIGN: We present the first-in-human clinical experience of a novel NIR fluorescent peptide, cRGD-ZW800-1, for the detection of colon cancer. cRGD-ZW800-1 was engineered to have an overall zwitterionic chemical structure and neutral charge to lower nonspecific uptake and thus background fluorescent signal. We performed a phase I study in 11 healthy volunteer as well as a phase II feasibility study in 12 patients undergoing an elective colon resection, assessing 0.005, 0.015, and 0.05 mg/kg cRGD-ZW800-1 for the intraoperative visualization of colon cancer. RESULTS: cRGD-ZW800-1 appears safe, and exhibited rapid elimination into urine after a single low intravenous dose. Minimal invasive intraoperative visualization of colon cancer through full-thickness bowel wall was possible after an intravenous bolus injection of 0.05 mg/kg at least 2 hours prior to surgery. Longer intervals between injection and imaging improved the tumor-to-background ratio. CONCLUSIONS: cRGD-ZW800-1 enabled fluorescence imaging of colon cancer in both open and minimal invasive surgeries. Further development of cRGD-ZW800-1 for widespread use in cancer surgery may be warranted given the ubiquitous overexpression of various integrins on different types of tumors and their vasculature.
32
Ahmedin Jemal, Freddie Bray, Jacques Ferlay et al. · CA A Cancer Journal for Clinicians · 2011 · 55K citations · Full text
Global cancer statistics, 2012
Lindsey A. Torre, Freddie Bray, Rebecca L. Siegel et al. · CA A Cancer Journal for Clinicians · 2015 · 27.4K citations · Full text
Renal clearance of quantum dots
Hak Soo Choi, Wenhao Liu, Preeti Misra et al. · Nature Biotechnology · 2007 · 4.4K citations · Full text
Maxime J.M. van der Valk, Denise E. Hilling, Esther Bastiaannet et al. · The Lancet · 2018 · 1.1K citations · Full text