Journal of Contemporary Brachytherapy · 2020 · 16 citations · 14 references
MedicineOncologyRadiation OncologyGynecologic OncologyGynecologic Radiation OncologyTreatment PlanningBrachytherapy For Gynecologic MalignanciesCancer Treatment PlanningCervical CancerRadiation TherapyRadiation Treatment PlanningTreatment Planning Dose CalculationCervical Cancer BrachytherapyCervical Cancer RadiotherapyClinical Target Volume ContouringClinical Target Volume DelineationDefinitive BrachytherapyLocally Advanced Cervical CancerRadiotherapy Plan EvaluationTumor Dosimetry
PURPOSE: The standard treatment for locally advanced stage cervical cancer is definitive radiotherapy, the quality of which affects both survival and side effects. Brachytherapy is a major component of definitive radiotherapy; it is administered using different techniques and applicators. The purpose of this study was to dosimetrically compare tandem ovoid (T-ovoid) and tandem ring (T-ring) brachytherapy treatments. MATERIAL AND METHODS: ) would be higher than 85 Gy, without exceeding the maximum dose for organs at risk. Then, pairwise dosimetric comparisons were performed. RESULTS: < 0.0001). CONCLUSIONS: In our study with a limited number of samples, T-ring applicator seems to offer better 3D brachytherapy dosimetry for both HR-CTV and nearby organs at risk.
14
Richard Pötter, Christine Haie-Méder, Erik Van Limbergen et al. · Radiotherapy and Oncology · 2006 · 1.6K citations
Medicine, Gynecology, Oncology +17
Kari Tanderup, Lars Fokdal, Alina Sturdza et al. · Radiotherapy and Oncology · 2016 · 356 citations
Taran Paulsen Hellebust, Christian Kirisits, Daniel Berger et al. · Radiotherapy and Oncology · 2010 · 321 citations