Physical review. D/Physical review. D. · 2020 · 39 citations · 59 references
Natural SciencesPhysicsNuclear PhysicsParticle PhysicsRadiation DetectionDetector TechnologyRadioactive DecayCalibration Data AnalysisNuclear RecoilTime Projection Chambers
We present a comprehensive analysis of electronic recoil vs nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014--2016 runs of the Large Underground Xenon experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with $\mathrm{S}1=120$ detected photons, i.e., equivalent to a nuclear recoil energy of $\ensuremath{\sim}100\text{ }\mathrm{keV}$, we observe an electronic recoil background acceptance of $<{10}^{\ensuremath{-}5}$ at a nuclear recoil signal acceptance of 50%. We also observe modest electric field dependence of the discrimination power, which peaks at a field of around $300\text{ }\text{ }\mathrm{V}/\mathrm{cm}$ over the range of fields explored in this study ($50--500\text{ }\text{ }\mathrm{V}/\mathrm{cm}$). In the weakly interacting massive particle search region of $\mathrm{S}1=1\ensuremath{-}80\text{ }\text{ }\mathrm{phd}$, the minimum electronic recoil leakage we observe is $(7.3\ifmmode\pm\else\textpm\fi{}0.6)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$, which is obtained for a drift field of $240--290\text{ }\text{ }\mathrm{V}/\mathrm{cm}$. Pulse shape discrimination is utilized to improve our results, and we find that, at low energies and low fields, there is an additional reduction in background leakage by a factor of up to 3. We develop an empirical model for recombination fluctuations which, when used alongside the Noble Element Scintillation Technique simulation package, correctly reproduces the skewness of the electronic recoil data. We use this updated simulation to study the width of the electronic recoil band, finding that its dominant contribution comes from electron-ion recombination fluctuations, followed in magnitude of contribution by fluctuations in the S1 signal, fluctuations in the S2 signal, and fluctuations in the total number of quanta produced for a given energy deposition.
59
Dark Matter Search Results from a One Ton-Year Exposure of XENON1T
E. Aprile, J. Aalbers, F. Agostini et al. · Physical Review Letters · 2018 · 1.9K citations · Full text
Results from a Search for Dark Matter in the Complete LUX Exposure
D. S. Akerib, S. Alsum, H. M. Araújo et al. · Physical Review Letters · 2017 · 1.6K citations · Full text
Dark Matter Results from 54-Ton-Day Exposure of PandaX-II Experiment
Xiangyi Cui, Abdusalam Abdukerim, Wei Chen et al. · Physical Review Letters · 2017 · 905 citations · Full text
Light Dark Matter Search with Ionization Signals in XENON1T
E. Aprile, J. Aalbers, F. Agostini et al. · Physical Review Letters · 2019 · 530 citations · Full text
Natural Sciences, Astronomy, Physics +10