High-energy X-ray radiographic image restoration is performed using a simulated radiation point spread function and an experimentally derived optical point spread function. It is shown that a robust method for removal of thick monolithic scintillator blur can be determined through independent examination of the blur components. We show that the scintillator blur for a 20 MeV end-point X-ray beam and 20 mm thick LYSO scintillator contributes significantly to the system blur. It is also shown that the optical scatter in the monolithic crystal degrades the low-frequency response of the system. The use of a simulated point spread function for image restoration using deconvolution provides a simple method for image restoration, thereby enhancing feature identification and areal density reconstruction.