Echocardiographic Results of Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients
132
Citations
23
References
2020
Year
In patients with severe aortic stenosis and low surgical risk, TAVR with the SAPIEN 3 valve was associated with similar percentage of moderate or severe AR compared with SAVR but higher percentage of mild AR. Transprosthetic gradients, valve areas, percentage of severe prosthesis-patient mismatch, and left ventricular mass regression were similar in TAVR and SAVR. SAVR was associated with significant deterioration of right ventricular systolic function and greater tricuspid regurgitation, which persisted at 1 year. High Z<sub>va</sub> and low tricuspid annulus plane systolic excursion were associated with worse outcome at 1 year whereas AR and severe prosthesis-patient mismatch were not. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02675114.