Publication | Open Access
Detection of Air and Surface Contamination by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) in Hospital Rooms of Infected Patients
97
Citations
12
References
2020
Year
Unknown Venue
Particle Size DistributionViral DiagnosticsAir Pollution FiltrationAir QualityVirus TransmissionCovid-19Hospital RoomsAir ContaminationEnvironmental HealthRespiratory InfectionInfection ControlPublic HealthInfected PatientsAir SamplingSurface ContaminationRespiratory DiseasesCovid-19 PandemicVirologySurface SamplesEpidemiologyEmerging Infectious DiseasesInfectious Respiratory DiseaseIndoor Air QualityAir PollutionMedicine
Abstract Understanding the particle size distribution in the air and patterns of environmental contamination of SARS-CoV-2 is essential for infection prevention policies. We aimed to detect SARS-CoV-2 surface and air contamination and study associated patient-level factors. 245 surface samples were collected from 30 airborne infection isolation rooms of COVID-19 patients, and air sampling was conducted in 3 rooms. Air sampling detected SARS-CoV-2 PCR-positive particles of sizes >4 µm and 1-4 µm in two rooms, which warrants further study of the airborne transmission potential of SARS-CoV-2. 56.7% of rooms had at least one environmental surface contaminated. High touch surface contamination was shown in ten (66.7%) out of 15 patients in the first week of illness, and three (20%) beyond the first week of illness (p = 0.010).