Journal of Engineering · 2011 · 11 citations · 0 references
EngineeringChemical EngineeringEnvironmental EngineeringMembrane ScienceWastewater TreatmentWater TreatmentMembrane FiltrationMembrane FoulingWastewater BiotreatmentWastewater CharacterizationMembrane Filtration DesignMembrane Filtration In Water TreatmentMembrane TreatmentMicrofiltrationPermeate FluxVolumetric Flow RateWastewater Treatment MembranesWater Treatment Membranes
This research was conducted using ceramic microfiltration membrane for treatment of oily wastewater in the pilot-scale dead-end filtration system designed in the laboratory under the influence of conditions of feed flow rate 15-35 l/h, feed temperature 32-48°C, oil feed concentration 300-1200 ppm, feed solution pH 2.6-9.8. The influence of these conditions on the permeate flux rate and oil rejection percent were investigated. Experimental results indicated that when feed flow rate increased to 35 l/h permeate fluxrates increased to 100 l/m2.h and oil rejection percent decreased to 70.1%, and when feed temperatureincreased to 48 ºC permeate flux rate increased to 62 l/m2.h and oil rejection percent decreased to 56.44%.But when oil feed concentration increased to 1200 ppm permeate flux rate decreased to 17.2 l/m2.h and oil rejection percent increased to 99.7%. Also basic feed solution (pH=9.8) gave high permeate flux rate(44.51 l/m2.h) and low oil rejection percent (84%) in comparison with acidic feed solution (pH=2.6) whichgave low permeate flux rate (26.42 l/m2.h) and high oil rejection percent (99.46%). Four classical modelswere investigated to flux decline and the results showed that the experimental data was consistent (R2 =0.9883) with the complete blocking filtration model.