Journal of Medical Economics · 2020 · 28 citations · 25 references
PharmacyCardiologyPharmacoeconomicsCost-effectiveness AnalysisHealth InsuranceInsurance EconomicsCost-effectiveness ModelingHealthcare Cost AnalysisImplant-associated InfectionImplantable Cardioverter-defibrillator CareMedical Device EvaluationMedical Device SafetyCardiac Implantable DevicesCardiac Implantable Electronic Device InfectionCardiac PacemakersDevice-associated InfectionsDevice-related InfectionsImplantable Cardioverter DefibrillatorsInfection Risk FactorsRetrospective Cost Analysis
Aims: Cardiac device infections (CDIs) are serious adverse events associated with morbidity and mortality, significant costs and increased healthcare utilization. The objective of the current study was to characterize the CDI rate by device type, risk factors for infection and healthcare costs from a large U.S. health insurer perspective.Materials and Methods: A retrospective analysis of a large U.S. health insurer database identified commercial and Medicare Advantage with Part D (MAPD) members ≥18 years with ≥1 claim for a cardiac implantable electronic device (CIED) procedure between 01 October 2011 and 31 October 2015. CIEDs included pacemakers (IPG), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy – pacemakers without (CRT-P) and with defibrillation (CRT-D). Probabilities of CDI through one-year post implant were estimated using the Kaplan–Meier method. A regression model with stepwise variable selection was used to select risk factors associated with CDIs.Results: A total of 63,406 patients were included with an overall CDI rate of 1.28% (1.0% de novo and 1.74% replacement devices), varying by device type: IPG = 0.91%; ICD = 1.63%; CRT-p = 1.50%; CRT-D = 2.22%. The average adjusted annual medical costs were 2.4 times greater [95% confidence interval (CI) = 2.1–2.7] for those with an infection compared to those without, and the incremental cost difference was estimated to be $57,322 [95% CI $46,572–$70,484]. Observed risk factors of CDIs included prior device infection [Odds ratio (OR) = 11.356; 95% CI = 7.923–16.276], undergoing a CIED replacement procedure (OR = 1.644; 95% CI = 1.361–1.987), implantation of a high-power device (OR = 1.354; 95% CI = 1.115–1.643), and younger age (age < 65) (OR = 1.607; 95% CI = 1.307–1.976).Conclusions: The CDI rate at one year ranged from 0.91%–2.22% depending on device type. Management of CDIs among commercial and MAPD members is associated with high healthcare expenditures.
25
Risk Factors Related to Infections of Implanted Pacemakers and Cardioverter-Defibrillators
Didier Klug, Mamadou Balde, Dominique Pavin et al. · Circulation · 2007 · 697 citations
Andrew Voigt, Alaa Shalaby, Samir Saba · Pacing and Clinical Electrophysiology · 2009 · 395 citations
Antibacterial Envelope to Prevent Cardiac Implantable Device Infection
Khaldoun G. Tarakji, Suneet Mittal, Charles Kennergren et al. · New England Journal of Medicine · 2019 · 387 citations · Full text
Medicine, Cardiology, Surgery +17
Jens Brock Johansen, Per Arnsbo, Peter Mortensen et al. · European Heart Journal · 2011 · 376 citations · Full text
Medicine, Cardiology, Surgery +17