Pacing and Clinical Electrophysiology · 2020 · 19 citations · 20 references
MedicineCardiologyPediatricsClinical CardiologyNeonatologyPediatric CardiologyCardiac PacingCongenital Heart DiseaseNeonatal CardiologyPediatric Cardiac ElectrophysiologyPediatric Cardiac PhysiologyPediatric EchocardiographyAtrioventricular Block PacingAtrioventricular SynchronyCardiac Systolic FunctionCongenital Atrioventricular BlockLeft Ventricular Systolic FunctionPacemaker ElectrocardiographyPacing For Pediatric PatientsVentricular Synchrony Assessment
BACKGROUND: Small retrospective studies reported that left ventricular (LV) pacing is likely to preserve LV function in children with isolated congenital complete atrioventricular block (CCAVB). The aim of this study was to prospectively evaluate LV contractility and synchrony in a cohort of neonates/infants at pacemaker implantation and follow-up. METHODS: Patients with CCAVB who underwent LV pacing were evaluated with electrocardiogram and echocardiogram in a single-center, prospective study. Data were collected at implantation, at 1-month and every year of follow-up, up to 5 years. LV ventricular dimensions (diameters and volumes), systolic function (ejection fraction [EF] and global longitudinal strain [GLS]), and synchrony were evaluated. Data are reported as median (25th-75th centiles). RESULTS: Twenty consecutive patients with CCAVB underwent pacemaker implantation (12 single-chamber pacemaker [VVIR] and eight dual-chamber pacemaker [DDD]) with epicardial leads: 17 on the LV apex and three on the free wall. Age at implantation was 0.3 months (1 day-4.5 months). Patients showed good clinical status, normal LV dimensions, preserved systolic function, and synchrony at 60 (30-60) months follow-up. EF increased to normal values in patients with preimplantation EF <50%. Presence of antibodies and pacing mode (DDD vs VVIR) had no impact on the outcome. CONCLUSIONS: LV pacing preserved LV systolic function and synchrony in neonates and infants with CCAVB at 5-year follow-up. LV EF improved in patients with low preimplantation EF. Pacing mode or the presence of autoantibodies did not demonstrated an impact on LV contractility and synchrony.
20
Panos Vardas, Angelo Auricchio, Jean Jacques Blanc et al. · EP Europace · 2007 · 290 citations · Full text
Karen A. Marcus, Annelies M. C. Mavinkurve‐Groothuis, Marlieke Barends et al. · Journal of the American Society of Echocardiography · 2011 · 199 citations
Medicine, Cardiology, Pediatrics +13