Measurement Science and Technology · 2020 · 11 citations · 27 references
EngineeringBiophysicsPhysiologyBiosensorsOpticsSensorsOptical BiosensingOptical BiosensorsOptical DiagnosticsOptical SensingOptical SensorsRed Blood Cell PhysiologyCell-based Optical BiosensorsHemolysis AssaysHemolysis MechanismsOptical Cell BiosensorsOsmotic FragilityRefractive Index BiosensingRefractive Index DeterminationRefractive Index Sensing
Abstract Identifying abnormalities in red blood cells can provide important medical clues for the diagnosis, prognosis, and treatment of some health disorders. A common test used to examine the conditions of erythrocytes in humans is osmotic fragility. The standard technique to determine the osmotic fragility of red blood cells is laborious and time-consuming, and provides only approximate values with a few experimental data. In this work, we propose and investigate a way to measure the osmotic fragility of erythrocytes, rapidly and in a straightforward, more quantitative and less laborious way, with an optical sensor. The basic idea is monitoring in real time the refractive index of a suspension of erythrocytes to follow the kinetics of their lysis as the hemoglobin-rich cytosol is released from the erythrocytes in the surrounding hypotonic solution during hemolysis, resulting in an increase of the refractive index. We propose a device to measure in real time the refractive index and demonstrate the feasibility of monitoring the hemolysis process with high resolution. Our results show that the release of hemoglobin-rich cytosol during the progress of the hemolysis of erythrocytes in hypotonic media is generally an exponential-like function of time. We provide a mathematical model that reproduces experimental curves effectively. We show results for erythrocytes obtained from human blood stored in a blood bank and from volunteers diagnosed with two different types of anemia: hemolytic and drepanocytic. We define times, measurable from the kinetics of the refractive index signal, to quantify the progress of hemolysis as a possible new method of measuring osmotic fragility.
27
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
George M. Hale, Marvin R. Querry · Applied Optics · 1973 · 4.4K citations
Clinical proteomics: Written in blood
Lance A. Liotta, Mauro Ferrari, Emanuel F. Petricoin · Nature · 2003 · 540 citations
Measurement of Red Cell Lifespan and Aging
Robert S. Franco · Transfusion Medicine and Hemotherapy · 2012 · 230 citations · Full text