Patient Preference and Adherence · 2020 · 37 citations · 20 references
PharmacyClinical PharmacyPharmacy PracticeDosage Form DesignDrug DeliveryPharmaceutical ComplianceAutomated Dispensing SystemsMedication AdherenceMedication Administration SystemsMedication Management SystemsMedication Use EvaluationPatient AdherenceAdherenceDrug Utilization AnalysisElectronic Medication MonitoringMedication Adherence AppsMedication Adherence MonitoringMedication Adherence Monitoring SystemsMedication Reminder SystemsRobustness Evaluation
PURPOSE: Smart medication adherence monitoring devices can provide objective and granular drug utilization data and help patients engaging with their treatment. In this proof-of-concept study, the acceptability and technical robustness of a novel smart pill bottle prototype (SPBP) were assessed in order to allow further optimization. METHODS: The SPBP is an app-controlled automatic dispense system, capturing real-time data on a web-based platform, which sends text reminders and measures storage conditions. A heterogeneous group of ten volunteers was asked to dispense placebo capsules with the SPBP and to follow a predefined dosing schedule for a trial period of 2 weeks. Afterwards, a questionnaire was filled out during a short interview. Primary outcome was dispense adherence as measured by the bottle. Other study outcomes included system acceptability (System Usability Scale [SUS]), self-reported adherence (MARS) and technical robustness of the bottle's mechanics (electronic pill dispenser) and sensors (bottle temperature). RESULTS: The overall dispense adherence rate as measured by the SPBP was 88%. All participants completed the study and four participants had an adherence rate of 100% during the study. The dispense adherence rates corresponded well with participants' self-reported adherence with an average MARS total score of 23.6 (out of 25). Participants judged the system easy to use, with a mean SUS score of 79.3 (range: 57.5-97.5). The overall mean temperature difference between the bottle sensor and calibrated external sensor was -0.82°C (range: -1.37°C to -0.21°C). CONCLUSION: The SPBP was well accepted and this study provides data for further optimization and follow-up studies. Smart adherence technologies such as these may change the way healthcare professionals, trialists and patients manage medication adherence.
20
Amy Hai Yan Chan, Alistair W. Stewart, Jeff Harrison et al. · The Lancet Respiratory Medicine · 2015 · 260 citations