IEEE Transactions on Industry Applications · 2020 · 93 citations · 22 references
EngineeringElectrical EngineeringFault-tolerant ComputingFault-tolerant SystemsPower ElectronicsDc-dc ConvertersDiagnosisDiagnosticsElectrical System DiagnosticsFault DetectionFault DiagnosisFault Diagnosis For Nonlinear SystemsFault Diagnosis In Power ConvertersInterleaved Dc-dc ConverterObserver-based DiagnosisOpen-circuit Fault DetectionParameter UncertaintyPower Electronics Fault DiagnosisRobustness
The power semiconductor device is one of the most fragile components of the dc-dc power converters in industrial applications. In this article, a Luenberger observer-based switch fault diagnosis method is proposed for the dc-dc interleaved boost converter for fuel cell (FC) application. The inductor current within the main controller system is selected as the diagnosis variable, avoiding the use of extra sensors. Moreover, an adaptive threshold is introduced to deal with the effects of the converter circuit parameter uncertainty, and the converter operation point variation resulted from FC nonlinear volt-ampere characteristic. The proposed fast fault diagnosis method shows good robustness to false alarms. The simulation and experiment results demonstrate the robustness and validity of the proposed method.
22
Imed Jlassi, Jorge O. Estima, Séjir Khojet El Khil et al. · IEEE Transactions on Industry Applications · 2016 · 270 citations
Engineering, Electrical Engineering, Fault-tolerant Systems +16