Technetium-99m-labeled macroaggregated albumin lung perfusion scan for diagnosis of hepatopulmonary syndrome: A prospective study comparing brain uptake and whole-body uptake

He Zhao, Jiaywei Tsauo, Xiaowu Zhang, Huaiyuan Ma, Ningna Weng, Gongshun Tang, Xiao Li

World Journal of Gastroenterology · 2020 · 14 citations · 14 references

DOIFull text

Open access

Concepts

Abstract

BACKGROUND: ., diffuse or localized abnormally dilated pulmonary capillaries and pulmonary and pleural arteriovenous communications) and arterial oxygenation defects, preferably by contrast-enhanced echocardiography and measurement of the alveolar-arterial oxygen gradient, respectively. AIM: To compare brain and whole-body uptake of technetium for diagnosing HPS. METHODS: Sixty-nine patients with chronic liver disease and/or portal hypertension were prospectively included. Brain uptake and whole-body uptake were calculated using the geometric mean of technetium counts in the brain and lungs and in the entire body and lungs, respectively. RESULTS: = 0.025). The optimal cut-off values of brain uptake and whole-body uptake for detecting IPVD were 5.7% and 42.5%, respectively, based on Youden's index. The sensitivity, specificity, and accuracy of brain uptake > 5.7% and whole-body uptake > 42.5% for detecting IPVD were 23%, 89%, and 59% and 100%, 52%, and 74%, respectively. CONCLUSION: Whole-body uptake is superior to brain uptake for diagnosing HPS.

References

14