Journal of Cardiovascular Electrophysiology · 2020 · 25 citations · 18 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologyPulmonologyAblation TherapyAtrial FibrillationCatheter AblationAblation TechnologyAblation WorkflowFluoroscopy Time AnalysisParoxysmal Atrial FibrillationPercutaneous AblationPower Delivery EfficiencyPulmonary Vein IsolationSurgical Ablation
AIMS: "CLOSE"-guided pulmonary vein isolation (PVI) is based on contiguous (≤6 mm) and optimized radiofrequency (RF) ablation lesions (ablation index [AI] ≥ 400 posteriorly and ≥ 550 anteriorly]. However, the optimal RF power to reach the desired AI is unknown. Therefore we evaluated the efficiency of an ablation strategy using higher power (40 W) during a first "CLOSE"-guided PVI. METHODS: Eighty consecutive patients undergoing "CLOSE"-guided PVI for symptomatic paroxysmal atrial fibrillation were ablated with 40 W (group A). Results were compared with 105 consecutive patients enrolled in the "CLOSE to CURE"-study and were ablated using the same protocol with 35 W (group B). RESULTS: In group A, ablation was associated with shorter ablation procedure time (91 vs 111 minutes; P < .001), shorter fluoroscopy time (5 vs 11 minutes; P < .001), shorter PVI time (48 vs 64 minutes; P < .001), shorter RF time (20 vs 28 minutes; P < .001), lower RF time per application (22 vs 29 seconds; P < .001), less RF applications (52 vs 58; P < .001), and less catheter dislocations (1 vs 2; P = .002). The impedance drop (12 vs 13 Ω; P = .192), first-pass isolation rate (99% vs 93%; P = .141) and acute reconnection rate (6% vs 4%; P > .733) were similar in both groups (groups A and B, respectively). No complications occurred. In group A, a gastroscopy-performed in five patients with esophageal temperature rise more than 42°C-did not reveal any esophageal lesion. Postprocedural recurrence of atrial tachyarrhythmia at 1 year was not significantly different between both groups. CONCLUSIONS: Using the "CLOSE"-protocol, increased power increases the efficiency of PVI without compromising patients' safety.
18
Thomas Phlips, Philippe Taghji, Milad El Haddad et al. · EP Europace · 2018 · 359 citations · Full text
Medicine, Cardiology, Surgery +13
Philippe Taghji, Milad El Haddad, Thomas Phlips et al. · JACC. Clinical electrophysiology · 2017 · 348 citations
Moloy Das, Jonathan J. Loveday, Gareth Wynn et al. · EP Europace · 2016 · 345 citations · Full text
RF Catheter Ablation: Lessons on Lesions
Fred H.M. Wittkampf, Hiroshi Nakagawa · Pacing and Clinical Electrophysiology · 2006 · 286 citations
Medicine, Cardiology, Heat Transfer +15