Scientific Reports · 2020 · 190 citations · 35 references
MedicineBiomedical EngineeringCardiologyBiomedical Signal ProcessingElectrophysiologyMachine LearningAtrial FibrillationCardiac ArrhythmiasCardiac Signal ProcessingClassificationElectrocardiogram AnalysisElectrocardiography12-Lead ElectrocardiographyClassification AccuracyClassification AlgorithmsEcg Feature ExtractionElectrocardiogram Feature ExtractionExtreme Gradient BoostingGradient BoostingGradient Boosting Trees
Abstract Arrhythmia constitutes a problem with the rate or rhythm of the heartbeat, and an early diagnosis is essential for the timely inception of successful treatment. We have jointly optimized the entire multi-stage arrhythmia classification scheme based on 12-lead surface ECGs that attains the accuracy performance level of professional cardiologists. The new approach is comprised of a three-step noise reduction stage, a novel feature extraction method and an optimal classification model with finely tuned hyperparameters. We carried out an exhaustive study comparing thousands of competing classification algorithms that were trained on our proprietary, large and expertly labeled dataset consisting of 12-lead ECGs from 40,258 patients with four arrhythmia classes: atrial fibrillation, general supraventricular tachycardia, sinus bradycardia and sinus rhythm including sinus irregularity rhythm. Our results show that the optimal approach consisted of Low Band Pass filter, Robust LOESS, Non Local Means smoothing, a proprietary feature extraction method based on percentiles of the empirical distribution of ratios of interval lengths and magnitudes of peaks and valleys, and Extreme Gradient Boosting Tree classifier, achieved an F 1 -Score of 0.988 on patients without additional cardiac conditions. The same noise reduction and feature extraction methods combined with Gradient Boosting Tree classifier achieved an F 1 -Score of 0.97 on patients with additional cardiac conditions. Our method achieved the highest classification accuracy (average 10-fold cross-validation F 1 -Score of 0.992) using an external validation data, MIT-BIH arrhythmia database. The proposed optimal multi-stage arrhythmia classification approach can dramatically benefit automatic ECG data analysis by providing cardiologist level accuracy and robust compatibility with various ECG data sources.
35
Leo Breiman · Machine Learning · 2001 · 126.2K citations · Full text
Scikit-learn: Machine Learning in Python
Fabián Pedregosa, Gaël Varoquaux, Alexandre Gramfort et al. · arXiv (Cornell University) · 2012 · 63.7K citations · Full text
Greedy function approximation: A gradient boosting machine.
Jerome H. Friedman · The Annals of Statistics · 2001 · 29K citations · Full text