IEEE Transactions on Medical Imaging · 2020 · 60 citations · 35 references
MedicineBiomedical EngineeringRadiologyDiagnostic ImagingUltrasonographyUltrasoundMedical Image AnalysisMedical ImagingThree-dimensional UltrasonographyThree-dimensional UltrasoundVascular ImagingVolume Segmentation3D Image Segmentation3D Medical Image AnalysisCommon Carotid ArteryContinuous FlowImage-based Volume SegmentationPlaque Burden QuantificationUltrasound Image SegmentationVascular Segmentation
Vessel-wall-volume (VWV) is an important three-dimensional ultrasound (3DUS) metric used in the assessment of carotid plaque burden and monitoring changes in carotid atherosclerosis in response to medical treatment. To generate the VWV measurement, we proposed an approach that combined a voxel-based fully convolution network (Voxel-FCN) and a continuous max-flow module to automatically segment the carotid media-adventitia (MAB) and lumen-intima boundaries (LIB) from 3DUS images. Voxel-FCN includes an encoder consisting of a general 3D CNN and a 3D pyramid pooling module to extract spatial and contextual information, and a decoder using a concatenating module with an attention mechanism to fuse multi-level features extracted by the encoder. A continuous max-flow algorithm is used to improve the coarse segmentation provided by the Voxel-FCN. Using 1007 3DUS images, our approach yielded a Dice-similarity-coefficient (DSC) of 93.2±3.0% for the MAB in the common carotid artery (CCA), and 91.9±5.0% in the bifurcation by comparing algorithm and expert manual segmentations. We achieved a DSC of 89.5±6.7% and 89.3±6.8% for the LIB in the CCA and the bifurcation respectively. The mean errors between the algorithm-and manually-generated VWVs were 0.2±51.2 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> for the CCA and -4.0±98.2 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> for the bifurcation. The algorithm segmentation accuracy was comparable to intra-observer manual segmentation but our approach required less than 1s, which will not alter the clinical work-flow as 10s is required to image one side of the neck. Therefore, we believe that the proposed method could be used clinically for generating VWV to monitor progression and regression of carotid plaques.
35
Liang-Chieh Chen, George Papandreou, Iasonas Kokkinos et al. · IEEE Transactions on Pattern Analysis and Machine Intelligence · 2017 · 22.1K citations
Neural networks for pattern recognition
Choice Reviews Online · 1994 · 18.7K citations
Hengshuang Zhao, Jianping Shi, Xiaojuan Qi et al. · 2017 · 15.5K citations
Squeeze-and-Excitation Networks
Jie Hu, Li Shen, Samuel Albanie et al. · IEEE Transactions on Pattern Analysis and Machine Intelligence · 2019 · 12.5K citations