IEEE Transactions on Dielectrics and Electrical Insulation · 2020 · 56 citations · 14 references
Natural SciencesElectrical EngineeringMaterials ScienceElectronic MaterialsEnergy MaterialsPower ElectronicsDielectric MaterialsDielectric PropertiesDielectricsElectrical ConductivityInsulation MaterialsInsulation SystemsBreakdown StrengthDielectric StrengthElectrical Insulation MaterialsGaseous InsulationHigh-voltage Direct Current ApplicationsHigh-voltage InsulationInsulation Materials CharacterizationPartial Discharge
Recent studies have demonstrated that fluoronitrile (FN) Novec™ 4710 and fluoroketone (FK) Novec™ 5110 show higher dielectric strength than SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> . These gases can be mixed with a buffer gas such as CO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> and technical air to have suitable dielectric properties for high voltage insulation applications. With the rapid growth of HVDC networks, these gases may replace SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> in future HVDC apparatus such as GIS/GIL. This paper focuses on the study of the partial discharge (PD) characteristics of SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> and SF6 alternative gases with a protrusion defect on the high voltage conductor with DC voltage. The results show that, for calculated equivalent SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> dielectric strength under homogeneous electric field, a difference in terms of partial discharge inception voltage was noted for gas mixtures compared to SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> . This difference may be due to the influence of gas pressure under highly inhomogeneous electric field. FN-CO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> and FK-Air mixtures showed the highest PD amplitude under positive polarity while it was higher under negative polarity for SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> . Moreover, PD repetition frequency is higher for SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> investigated alternative gases. The results can help for the design of SF <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">6</sub> free HVDC GIS partial discharge monitoring system.
14
Abderrahmane Béroual, A. Haddad · Energies · 2017 · 209 citations · Full text
Engineering, Electrical Engineering, Environmental Engineering +14