Magnetic Resonance in Medicine · 2020 · 26 citations · 41 references
MedicineBioengineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyCardiovascular ImagingMagnetic Resonance ImagingMedical ImagingVascular ImagingMagnetic Resonance AngiographyNoncontrast Vascular ImagingPulse Sequence DesignSaturation
PURPOSE: Most existing non-contrast-enhanced methods for abdominal MR arteriography rely on a spatially selective inversion (SSI) pulse with a delay to null both static tissue and venous blood, and are limited to small spatial coverage due to the sensitivity to slow arterial inflow. Velocity-selective inversion (VSI) based approach has been shown to preserve the arterial blood inside the imaging volume at 1.5 T. Recently, velocity-selective saturation (VSS) pulse trains were applied to suppress the static tissue and have been combined with SSI pulses for cerebral MR arteriography at 3 T. The aim of this study is to construct an abdominal MRA protocol with large spatial coverage at 3 T using advanced velocity-selective pulse trains. METHODS: Multiple velocity-selective MRA protocols with different sequence modules and 3D acquisition methods were evaluated. Sequences using VSS only as well as SSI+VSS and VSI+VSS preparations were then compared among a group of healthy young and middle-aged volunteers. Using MRA without any preparations as reference, relative signal ratios and relative contrast ratios of different vascular segments were quantitatively analyzed. RESULTS: Both SSI+VSS and VSI+VSS arteriograms achieved high artery-to-tissue and artery-to-vein relative contrast ratios above aortic bifurcation. The SSI+VSS sequence yielded lower signal at the bilateral iliac arteries than VSI+VSS, reflecting the benefit of the VSI preparation for imaging the distal branches. CONCLUSION: The feasibility of noncontrast 3D MR abdominal arteriography was demonstrated on healthy volunteers using a combination of VSS pulse trains and SSI or VSI pulse.
41
Michael Lustig, David L. Donoho, Juan M. Santos et al. · IEEE Signal Processing Magazine · 2008 · 2.3K citations
Intracranial Gadolinium Deposition after Contrast-enhanced MR Imaging
Robert J. McDonald, Jennifer S. McDonald, David F. Kallmes et al. · Radiology · 2015 · 1.3K citations
Medicine, Neuroscience, Radiology +14
Nephrogenic Systemic Fibrosis: Risk Factors and Incidence Estimation
Elizabeth A. Sadowski, Lindsey Bennett, Micah R. Chan et al. · Radiology · 2007 · 1K citations
Medicine, Nephrology, Pathology +12
Gadolinium-enhanced MR aortography.
Martin R. Prince · Radiology · 1994 · 895 citations