Journal of Clinical Microbiology · 2020 · 37 citations · 10 references
Life SciencesImmunologyInfectious DiseasesClinical ImmunologyEarly DetectionMedical MicrobiologyAntigen Detection AssaysDiagnostic ImmunologyInfectious Disease ScreeningLateral Flow ImmunoassaysPathogen DetectionSerological DiagnosticsCryptococcal Antigen ScreeningCryptococcal Disease ScreeningCryptococcal MeningitisDiagnostic Performance MetricsInfectious Disease DiagnosticsLateral Flow AssaysQuantitative Lateral Flow AssaysReference Standard Construction
= 2) yielded Positive results. The CryptoPS assay missed 35% (7/20) of samples with CrAg LFA titers of ≤1:20. The new semiquantitative CrAg LFAs allow rapid estimation of titer levels in easy-to-perform platforms. The CrAgSQ demonstrated better qualitative sensitivity and specificity than the CryptoPS compared to the reference standard. The exact grading of the CrAgSQ results has some subjectivity, with interreader variability; however, qualitative reads were generally concordant for both assays.
10
David B. Meya, Yukari C. Manabe, Barbara Castelnuovo et al. · Clinical Infectious Diseases · 2010 · 303 citations · Full text
Joseph N Jarvis, Ann Percival, Sean K. Bauman et al. · Clinical Infectious Diseases · 2011 · 295 citations