Neurospine · 2020 · 17 citations · 22 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryDiagnostic ImagingDiagnostic RadiologySpine SurgeryOrthopedic ExaminationPediatric ScoliosisPediatric Spinal AssessmentPediatric Spine DeformitySpinal AssessmentSpine ImagingInterobserver Reliability AssessmentInterobserver ReproducibilityIntraclass CorrelationPediatric Scoliosis SurgeryRadiographic Evaluation Of ScoliosisRadiographic Spinal AssessmentReliability Of Spinal Tests
OBJECTIVE: The objective was to compare Cobb angle measurements performed using an Oxford Cobbmeter and digital computer software (Surgimap) in a series of 83 adolescent idiopathic scoliosis (AIS) patients. METHODS: Two independent observers measured the Cobb angles for 123 curves on 83 consecutive long radiographs of patients with AIS using both Oxford Cobbmeter and digital computer software (Surgimap). The measurements were repeated a week. Curves were classified according to the severity into mild, moderate, and severe. The results were statistically analyzed for intraobserver and interobserver reliability. RESULTS: The mean Cobb angle was 48.12° ± 19.75° (range, 10.54°-110.76°). Globally the results of curve measurements were comparable between and within both observers using both methods, with small mean differences. According to intraclass correlation coefficient, there was high inter- and intraobserver high agreement for both methods. All readings were > 0.9. There was a good interobserver (κ = 0.745, 0.693) and a very good interobserver agreement (κ = 0.810, 0.804) for both methods for curve classification. However, poor agreement was observed as regards to the measurement time, being less with Oxford Cobbometer. CONCLUSION: The results of this study indicate that the Surgimap digital computer software measurement is an equivalent measuring tool to the Oxford Cobbmeter in Cobb angle measurement. Both have high intra and interobserver agreement for measurement and for curve classification, with small measurement differences. Oxford Cobbmeter is advantageous in being quicker, and therefore it is the method of choice for manual measurement, where PACS (patient archiving and communication system) or digital system is not available.
22
Outlines for the study of scoliosis
Cobb, J. L. Cobb, John R. Cobb et al. · Journal of Bone and Joint Surgery · 1948 · 1.2K citations
Outline for study of scoliosis
John R. Cobb · Journal of Bone and Joint Surgery · 1948 · 740 citations
Raymond T. Morrissy, G S Goldsmith, editors-in-chief Chittaranjan Kole and Timothy C. Hall et al. · Journal of Bone and Joint Surgery · 1990 · 621 citations
Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic
Hans Svanholm, H Starklint, H.J.G. Gundersen et al. · Apmis · 1989 · 455 citations