Physica Medica · 2020 · 38 citations · 20 references
MedicineRadiation OncologyMedical PhysicsRadiation TransportTreatment PlanningMonte Carlo DosimetryMonte Carlo MethodsMonte Carlo SimulationProton DosimetryProton TherapyRadiation TherapyComputerized Treatment PlanningMonte Carlo Dose CorrectionMonte Carlo Dose ModelingMonte Carlo Dose SimulationProton Therapy DosimetryProton Therapy Phantom DosimetryTreatment Quality Assurance
For radiation therapy, it is crucial to ensure that the delivered dose matches the planned dose. Errors in the dose calculations done in the treatment planning system (TPS), treatment delivery errors, other software bugs or data corruption during transfer might lead to significant differences between predicted and delivered doses. As such, patient specific quality assurance (QA) of dose distributions, through experimental validation of individual fields, is necessary. These measurement based approaches, however, are performed with 2D detectors, with limited resolution and in a water phantom. Moreover, they are work intensive and often impose a bottleneck to treatment efficiency. In this work, we investigated the potential to replace measurement-based approach with a simulation-based patient specific QA using a Monte Carlo (MC) code as independent dose calculation engine in combination with treatment log files. Our developed QA platform is composed of a web interface, servers and computation scripts, and is capable to autonomously launch simulations, identify and report dosimetric inconsistencies. To validate the beam model of independent MC engine, in-water simulations of mono-energetic layers and 30 SOBP-type dose distributions were performed. Average Gamma passing ratio 99 ± 0.5% for criteria 2%/2 mm was observed. To demonstrate feasibility of the proposed approach, 10 clinical cases such as head and neck, intracranial indications and craniospinal axis, were retrospectively evaluated via the QA platform. The results obtained via QA platform were compared to QA results obtained by measurement-based approach. This comparison demonstrated consistency between the methods, while the proposed approach significantly reduced in-room time required for QA procedures.
20
A technique for the quantitative evaluation of dose distributions
Daniel A. Low, William B. Harms, Sasa Mutic et al. · Medical Physics · 1998 · 2.9K citations · Full text
Evaluation of the gamma dose distribution comparison method
Daniel A. Low, James F. Dempsey · Medical Physics · 2003 · 752 citations
Intensity modulation methods for proton radiotherapy
Antony Lomax · Physics in Medicine and Biology · 1999 · 536 citations
Correction of CT artifacts and its influence on Monte Carlo dose calculations
Magdalena Bazalova‐Carter, Luc Beaulieu, S Palefsky et al. · Medical Physics · 2007 · 140 citations