IEEE Transactions on Industrial Electronics · 2020 · 62 citations · 18 references
EngineeringMechanical EngineeringElectric MachinesHeat TransferThermal AnalysisElectric MotorsMachine CoolingMagnetic Circuit AnalysisPermanent Magnet MachinesThermal DesignDouble-layer WindingsElectromagnetic DesignElectromagnetic Performance AnalysisHeat DissipationHeat Dissipation AnalysisHeat Transfer In Electrical MachinesTemperature Rise AnalysisThermal Network Modeling
In this article, a water-cooled structure with water-cooled plates between the primary double-layer windings field of the primary structure under short-term high overload conditions and periodic operations is calculated. Second, the heat dissipation effects of two different waterway topologies are designed and compared. Based on the thermal network analysis model and multiphysical field coupling model, the heat dissipation effect of the water-cooled motor is obtained. In order to obtain the maximum sustainable working current that the motor can withstand under water-cooled conditions, a fast calculation model-response surface model-is established and the electromagnetic performance of the water-cooled motor is obtained. The analysis results show that the temperature rise of the water-cooled motor decreases greatly, and the average thrust increases by 2.73 times. Finally, the calculated and tested results of the prototype are compared and analyzed.
18
D.A. Staton, Aldo Boglietti, Andrea Cavagnino · IEEE Transactions on Energy Conversion · 2005 · 620 citations · Full text
Engineering, Electrical Engineering, Mechanical Engineering +17