Journal of Biomedical Optics · 2020 · 50 citations · 41 references
EngineeringBioengineeringBiomedical EngineeringBiomedical ImagingBiomedical OpticsDiagnostic ImagingAbsorption In TissueMedical ImagingOptical ImagingScattering In TissueTissue Optical PropertiesTissue OpticsDiffuse Optical ImagingOptical AbsorptionOptical Absorption CoefficientOptical Characterization Of Biological TissueQuantitative Optical ImagingReduced Scattering CoefficientScatteringSpatial Frequency Domain Imaging
<bold>Significance</bold>: Spatial frequency domain imaging (SFDI) is a diffuse optical measurement technique that can quantify tissue optical absorption (μ<sub>a</sub>) and reduced scattering (<inline-formula><mml:math display="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>μ</mml:mi></mml:mrow><mml:mrow><mml:mi>s</mml:mi></mml:mrow><mml:mrow><mml:mo>′</mml:mo></mml:mrow></mml:msubsup></mml:mrow></mml:math></inline-formula>) on a pixel-by-pixel basis. Measurements of μ<sub>a</sub> at different wavelengths enable the extraction of molar concentrations of tissue chromophores over a wide field, providing a noncontact and label-free means to assess tissue viability, oxygenation, microarchitecture, and molecular content. We present here openSFDI: an open-source guide for building a low-cost, small-footprint, three-wavelength SFDI system capable of quantifying μ<sub>a</sub> and <inline-formula><mml:math display="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>μ</mml:mi></mml:mrow><mml:mrow><mml:mi>s</mml:mi></mml:mrow><mml:mrow><mml:mo>′</mml:mo></mml:mrow></mml:msubsup></mml:mrow></mml:math></inline-formula> as well as oxyhemoglobin and deoxyhemoglobin concentrations in biological tissue. The companion website provides a complete parts list along with detailed instructions for assembling the openSFDI system. <bold>Aim</bold>: We describe the design of openSFDI and report on the accuracy and precision of optical property extractions for three different systems fabricated according to the instructions on the openSFDI website. <bold>Approach</bold>: Accuracy was assessed by measuring nine tissue-simulating optical phantoms with a physiologically relevant range of μ<sub>a</sub> and <inline-formula><mml:math display="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>μ</mml:mi></mml:mrow><mml:mrow><mml:mi>s</mml:mi></mml:mrow><mml:mrow><mml:mo>′</mml:mo></mml:mrow></mml:msubsup></mml:mrow></mml:math></inline-formula> with the openSFDI systems and a commercial SFDI device. Precision was assessed by repeatedly measuring the same phantom over 1 h. <bold>Results</bold>: The openSFDI systems had an error of 0 ± 6 % in μ<sub>a</sub> and −2 ± 3 % in <inline-formula><mml:math display="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>μ</mml:mi></mml:mrow><mml:mrow><mml:mi>s</mml:mi></mml:mrow><mml:mrow><mml:mo>′</mml:mo></mml:mrow></mml:msubsup></mml:mrow></mml:math></inline-formula>, compared to a commercial SFDI system. Bland–Altman analysis revealed the limits of agreement between the two systems to be ± 0.004 mm<sup> − 1</sup> for μ<sub>a</sub> and −0.06 to 0.1 mm<sup> − 1</sup> for <inline-formula><mml:math display="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>μ</mml:mi></mml:mrow><mml:mrow><mml:mi>s</mml:mi></mml:mrow><mml:mrow><mml:mo>′</mml:mo></mml:mrow></mml:msubsup></mml:mrow></mml:math></inline-formula>. The openSFDI system had low drift with an average standard deviation of 0.0007 mm<sup> − 1</sup> and 0.05 mm<sup> − 1</sup> in μ<sub>a</sub> and <inline-formula><mml:math display="inline" xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mrow><mml:msubsup><mml:mrow><mml:mi>μ</mml:mi></mml:mrow><mml:mrow><mml:mi>s</mml:mi></mml:mrow><mml:mrow><mml:mo>′</mml:mo></mml:mrow></mml:msubsup></mml:mrow></mml:math></inline-formula>, respectively. <bold>Conclusion</bold>: The openSFDI provides a customizable hardware platform for research groups seeking to utilize SFDI for quantitative diffuse optical imaging.
41
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
Hugo J. van Staveren, Christian J. M. Moes, Jan van Marie et al. · Applied Optics · 1991 · 1.1K citations