IEEE Transactions on Industry Applications · 2020 · 25 citations · 21 references
EngineeringElectrical EngineeringElectric MachinesEnergy SystemsPower ElectronicsDirect Current MachinesElectric MotorsInduction MachinesLosses In Electric MachinesMachine HeatingPower QualityElectrical Power QualityHarmonic DistortionInduction MotorsMotor EfficiencyMotor LossesNegative Sequence CurrentsPower Quality StandardsVoltage Unbalance
Heating and losses of induction motor (IM) grow with the supply voltage unbalance and harmonic distortion. To avoid thermal overload, the IEEE 141-1993, the IEEE 3004.8, NEMA MG1-2014, and the IEC 60034-26 standards establish derating factors for IMs operating under those conditions. In this article, we show that while the derating factors proposed by these standards adequately protect standard-efficiency IMs, they are only marginally adequate to protect modern higher-efficiency IMs. To this end, we compare the derating factors provided by the standards with the derating factors required to maintain the losses at rated values in a standard-efficiency IM, in a premium-efficiency IM, and in a super-premium-efficiency IM. To extrapolate the results from these IM, we compared the nameplate data of 548 IMs of different efficiency classes and found that higher efficiency classes correlate to higher IM starting currents and lower impedances to the negative sequence and harmonic voltages. These lower impedances in turn may lead to higher losses for unbalanced and harmonic voltages conditions.
21
Electrical power systems quality
M. McGranaghan, R.C. Dugan, H. Wayne Beaty · Choice Reviews Online · 1996 · 2.6K citations · Full text