Journal of Computer Assisted Tomography · 2020 · 13 citations · 20 references
MedicineCardiologyRadiologyDiagnostic ImagingDiagnostic RadiologyTreatment PlanningAortic ImagingCardiothoracic ImagingComputed TomographyImage QualityImage Quality AssessmentImage Quality AssuranceAortic Valve ImagingComputed Tomography AngiographyComputed Tomography Dose IndicesDose-length ProductImage Acquisition QualityRadiation Dose AssessmentSubjective Image Quality AssessmentTomographic Image Quality
OBJECTIVE: To evaluate image quality and radiation dose exposure of low-kV setting and low-volume contrast medium (CM) computed tomography angiography (CTA) protocol for transcatheter aortic valve implantation (TAVI) planning in comparison with standard CTA protocol. METHODS: Sixty-patients were examined with 256-row MDCT for TAVI planning: 32 patients (study group) were evaluated using 80-kV electrocardiogram-gated protocol with 60 mL of CM and IMR reconstruction; 28 patients underwent a standard electrocardiogram-gated CTA study (100 kV; 80 mL of CM; iDose4 reconstruction). Subjective and objective image quality was evaluated in each patient at different aortic levels. Finally, we collected radiation dose exposure data (CT dose index and dose-length product) of both groups. RESULTS: In study protocol, significant higher mean attenuation values were achieved in all measurements compared with the standard protocol. There were no significant differences in the subjective image quality evaluation in both groups. Mean dose-length product of study group was 56% lower than in the control one (P < 0.0001). CONCLUSION: Low-kV and low-CM volume CTA, combined with IMR, allows to correctly performing TAVI planning with high-quality images and significant radiation dose reduction compared with standard CTA protocol.
20
Burden of valvular heart diseases: a population-based study
Vuyisile T. Nkomo, Julius M. Gardin, Thomas N. Skelton et al. · The Lancet · 2006 · 4.8K citations
Stephan Achenbach, Victoria Delgado, Jörg Hausleiter et al. · Journal of cardiovascular computed tomography · 2012 · 629 citations
Medicine, Cardiology, Surgery +17
Noninvasive Evaluation of the Aortic Root With Multislice Computed Tomography
Laurens F. Tops, David Wood, Victoria Delgado et al. · JACC. Cardiovascular imaging · 2008 · 520 citations
Medicine, Cardiology, Radiology +15
Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose
Sebastian Leschka, Paul Stolzmann, Florian Schmid et al. · European Radiology · 2008 · 292 citations · Full text
Medicine, Cardiology, Radiology +14