Scanning · 2019 · 12 citations · 25 references
DentistryEndodonticsPeriodonticsCavity PreparationEndodontic InstrumentationEndodontic SurgeryDental ImagingRoot Fracture DetectionRoot-end Cavity PreparationCrack FormationCrack Pattern FormationCracksMicro-computed Tomography AssessmentRoot-end Resection InstrumentationRoot-end Resection TechniqueUltrasonic Cavity PreparationUltrasonic Root-end Cavity Preparation
Objective . This study is aimed at determining (1) the effect of root-end resection, ultrasonic root-end preparation, and root-end filling on the incidence of crack formation and propagation by using a digital microscope (DM) and optical coherence tomography (OCT) and (2) the performance of OCT on the detection of cracks by comparing with microcomputed tomography (micro-CT) as a reference standard. Methodology . Thirty extracted lower incisors were endodontically treated and subjected to root-end resection and ultrasonic root-end cavity preparation. Then, the teeth were divided into three groups (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mml:mi>n</mml:mi><mml:mo>=</mml:mo><mml:mn>10</mml:mn></mml:math>, each), and the root-end cavity was either left unfilled or filled with mineral trioxide aggregate (MTA) or super-EBA. The resected surface was observed with OCT and DM after the root-end resection, ultrasonic root-end preparation, and root-end filling, and the frequency of incomplete and complete cracks were recorded. The observation was repeated after two weeks, one month, and two months, and micro-CT scans after two months were taken as the gold standard. Results . The DM results show dentinal crack formation in 47% of the samples following root-end resection and in 87% following ultrasonic preparation. After the ultrasonic preparation, no existing crack propagated to a complete crack, but new cracks were formed. MTA and super-EBA had no effect on crack formation. The Spearman correlation coefficient between OCT and DM was 0.186 (very weak correlation; <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M2"><mml:mi>p</mml:mi><mml:mo>=</mml:mo><mml:mn>0.015</mml:mn></mml:math>). Sensitivity and specificity in comparison to micro-CT were 0.50 and 0.55 in OCT and 1.00 and 0.35 in DM, respectively. McNemar’s test showed a significant difference between OCT and DM (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M3"><mml:mi>p</mml:mi><mml:mo><</mml:mo><mml:mn>0.05</mml:mn></mml:math>). Conclusion . Apical resection and ultrasonic preparation could form dentinal cracks. OCT and DM showed different detection frequencies of cracks with very weak correlation. DM showed superior sensitivity compared with OCT.
25
Physical and chemical properties of a new root-end filling material
M. Torabinejad, C HONG, Fraser McDonald et al. · Journal of Endodontics · 1995 · 1.5K citations
Ik‐Kyung Jang, Brett E. Bouma, Dong-Heon Kang et al. · Journal of the American College of Cardiology · 2002 · 1K citations
Optical coherence tomography and disease subtype in multiple sclerosis
Mathew Pulicken, Eliza Gordon‐Lipkin, Laura J. Balcer et al. · Neurology · 2007 · 298 citations
Medicine, Neurology, Ophthalmology +17