Accuracy of the Defining Characteristics of Fatigue in Patients with Heart Failure as Identified by the 6-Minute Walking Test

Vinícius Batista Santos, Camila Takáo Lopes, Lanay Dourado dos Anjos, Isis Begot, Flavio Cassiolatto, Solange Guizilinni, Rita Simone Lopes Moreira

International Journal of Nursing Knowledge · 2019 · 11 citations · 26 references

Concepts

Abstract

PURPOSE: Identify the prevalence of the nursing diagnosis (ND) Fatigue in patients with heart failure (HF) and to analyze the accuracy of its defining characteristics (DCs). METHODS: 50 patients were assessed for Fatigue through a distance ambulated <300m during the Six-Minute Walking Test (6MWT) and the report of insufficient energy. Sensitivity, specificity, positive and negative predictive values were calculated for the DCs associated with Fatigue. FINDINGS: The prevalence of Fatigue was 48%. No DCs were sensitive and specific for determining Fatigue. CONCLUSIONS: There were no DCs accurate enough to infer Fatigue. IMPLICATIONS FOR PRACTICE: A distance ambulated <300m during the 6MWT should be included as a DC of Fatigue.

References

26