Revista Brasileira de Terapia Intensiva · 2019 · 12 citations · 42 references
MedicineCardiologyPhysiologyClinical CardiologyPulmonary Function TestingPulmonologyCardiac AssessmentCardiac CatheterizationMechanical VentilationPositive End-expiratory PressurePulmonary Artery CatheterizationTricuspid RegurgitationCardiac OutputCardiac Output ChangesEchocardiographic Cardiac Output AssessmentIntracardiac EchocardiographyPositive End-expiratory Pressure EffectsPulmonary HemodynamicsSwan-ganz CatheterizationTricuspid Regurgitation Assessment
OBJECTIVE: To compare cardiac output measurements by transthoracic echocardiography and a pulmonary artery catheter in mechanically ventilated patients with high positive end-expiratory pressure. To evaluate the effect of tricuspid regurgitation. METHODS: Sixteen mechanically ventilated patients were studied. Cardiac output was measured by pulmonary artery catheterization and transthoracic echocardiography. Measurements were performed at different levels of positive end-expiratory pressure (10cmH2O, 15cmH2O, and 20cmH2O). The effect of tricuspid regurgitation on cardiac output measurement was evaluated. The intraclass correlation coefficient was studied; the mean error and limits of agreement were studied with the Bland-Altman plot. The error rate was calculated. RESULTS: Forty-four pairs of cardiac output measurements were obtained. An intraclass correlation coefficient of 0.908 was found (p < 0.001). The mean error was 0.44L/min for cardiac output values between 5 and 13L/min. The limits of agreement were 3.25L/min and -2.37L/min. With tricuspid insufficiency, the intraclass correlation coefficient was 0.791, and without tricuspid insufficiency, 0.935. Tricuspid insufficiency increased the error rate from 32% to 52%. CONCLUSIONS: In patients with high positive end-expiratory pressure, cardiac output measurement by transthoracic echocardiography is comparable to that with a pulmonary artery catheter. Tricuspid regurgitation influences the intraclass correlation coefficient. In patients with high positive end-expiratory pressure, the use of transthoracic echocardiography to measure cardiac output is comparable to invasive measures.
42
Roberto M. Lang, Luigi P. Badano, Victor Mor‐Avi et al. · Journal of the American Society of Echocardiography · 2015 · 18K citations · Full text
Sherif F. Nagueh, Otto A. Smiseth, Christopher P. Appleton et al. · Journal of the American Society of Echocardiography · 2016 · 6.7K citations · Full text
William A. Zoghbi, Maurice Enriquez‐Sarano, Elyse Foster et al. · Journal of the American Society of Echocardiography · 2003 · 4.1K citations · Full text
Medicine, Cardiology, Surgery +14