IEEE Transactions on Medical Imaging · 2019 · 19 citations · 31 references
EngineeringBioengineeringBiomedical EngineeringBiomedical ImagingDiagnostic ImagingThoracic ImagingLung VolumesPulmonary ImagingVentilation ModelingLung Ventilation ImagingLung Volume AssessmentLung Volume EstimationLung Volume QuantificationMedical Image RegistrationPulmonary Ventilation ImagingRegional Lung Function AssessmentRegional Lung Ventilation
Out-of-phase ventilation occurs when local regions of the lung reach their maximum or minimum volumes at breathing phases other than the global end inhalation or exhalation phases. This paper presents the N-phase local expansion ratio (LER <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">N</sub> ) as a surrogate for lung ventilation. A common approach to estimate lung ventilation is to use image registration to align the end exhalation and inhalation 3DCT images and then analyze the resulting correspondence map. This 2-phase local expansion ratio (LER <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> ) is limited because it ignores out-of-phase ventilation and thus may underestimate local lung ventilation. To overcome this limitation, LER <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">N</sub> measures the maximum ratio of local expansion and contraction over the entire breathing cycle. Comparing LER <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> to LER <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">N</sub> provides a means for detecting and characterizing locations of the lung that experience out-of-phase ventilation. We present a novel in-phase/out-of-phase ventilation (IOV) function plot to visualize and measure the amount of high-function IOV that occurs during a breathing cycle. Treatment planning 4DCT scans collected during coached breathing from 32 human subjects with lung cancer were analyzed in this study. Results show that out-of-phase breathing occurred in all subjects and that the spatial distribution of out-of-phase ventilation varied from subject to subject. For the 32 subjects analyzed, 50% of the out-of-phase regions on average were mislabeled as low-function by LER <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> (high-function threshold of 1.1, IOV threshold of 1.05). 4DCT and Xenon-enhanced CT of four sheep showed that LER <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">8</sub> is more accurate than LER2 for measuring lung ventilation.
31
elastix: A Toolbox for Intensity-Based Medical Image Registration
Stefan Klein, Marius Staring, Keelin Murphy et al. · IEEE Transactions on Medical Imaging · 2009 · 4.4K citations
Mechanical Properties of Lungs
Jere Mead · Physiological Reviews · 1961 · 1.7K citations
Tokihiro Yamamoto, Sven Kabus, Jens von Berg et al. · International Journal of Radiation Oncology*Biology*Physics · 2010 · 158 citations