American Journal of Veterinary Research · 2019 · 21 citations · 16 references
Veterinary MedicineVeterinary MicrobiologyVeterinary SurgeryDiagnostic MicrobiologyInfection PreventionMedical MicrobiologyAntibiotic ResistanceAntimicrobial BiomaterialsBacterial InfectionsVeterinary BacteriologyWound CareWound InfectionAmpc Beta-lactamase-mediated ResistanceAntibacterial CoatingsBacterial Wound InfectionExtended-spectrum Beta-lactamase ProductionMicrobial Adhesion InhibitionSustained Antimicrobial ActionSuture Anchor MaterialsSuture Material Properties
Abstract OBJECTIVE To investigate in vitro effects of triclosan coating of suture materials on the growth of clinically relevant bacteria isolated from wounds in dogs. SAMPLE 6 types of suture material and 10 isolates each of methicillin-susceptible Staphylococcus pseudintermedius , methicillin-resistant S pseudintermedius , Escherichia coli , and AmpC β-lactamase and extended-spectrum β-lactamase–producing E coli from clinical wound infections. PROCEDURES Isolates were cultured on Mueller-Hinton agar with 3 types of triclosan-coated suture, uncoated counterparts of the same suture types, and positive and negative controls. Zones of inhibition (ZOIs) were measured after overnight incubation. Sustained antimicrobial activity assays were performed with susceptible isolates. The ZOI measurements and durations of sustained antimicrobial activity were compared among suture types and isolates by statistical methods. Suture surface characteristics and bacterial adherence were evaluated qualitatively with scanning electron microscopy. RESULTS ZOIs were generated only by triclosan-coated materials; triclosan-coated suture had sustained antimicrobial activity (inhibition) for 3 to 29 days against all tested pathogens. The ZOIs around triclosan-coated suture were significantly greater for S pseudintermedius isolates than for E coli isolates. Bacterial adherence to uncoated polyglactin-910 was greatest, followed by triclosan-coated polyglactin-910, and then uncoated monofilament sutures, with least adherence to coated monofilament sutures. CONCLUSIONS AND CLINICAL RELEVANCE Surface characteristics of suture materials may be as important or more important than triclosan coating for microbial inhibition; however, triclosan coating appeared to affect bacterial adherence for multifilament sutures. Triclosan-coated, particularly monofilament, sutures inhibited pathogens commonly isolated from wounds of dogs, including multidrug-resistant bacteria. Further studies are required to assess clinical efficacy of triclosan-coated suture materials in vivo.
16
Vincent Perreten, Kristina Kadlec, Štefan Schwarz et al. · Journal of Antimicrobial Chemotherapy · 2010 · 487 citations · Full text
Factors influencing wound dehiscence
Jon R. Cohen, Houston Johnson · The American Journal of Surgery · 1992 · 312 citations
Stephen Rothenburger, Daniel Spangler, Shubhangi Bhende et al. · Surgical Infections · 2002 · 180 citations
Bacterial Adherence to Suture Materials
Brendan D. Masini, Daniel J. Stinner, Scott M. Waterman et al. · Journal of surgical education · 2010 · 154 citations