IEEE Sensors Journal · 2019 · 24 citations · 43 references
Natural SciencesChemistryMaterials ScienceAnalytical ChemistryPolymer ChemistrySensorsAcoustic SensorsChemical SensorsElectrochemical DetectionElectrochemical SensorsEnvironmental BiosensorsSensor MaterialsCalibration CurvesDetectionHeavy Metal Ion DetectionLead DetectionPolymer SensorsSelectivitySensing In Aqueous MediaSurface Acoustic Wave Sensors
104 MHz surface acoustic wave sensors, functionalized with two polypyrrole (PPy) imprinted polymers, were designed for lead ion detection in liquid media. The main difference between the two ionic imprinted polymers (IIP) is related to the nature of the chelating agent: L-Cysteine (LCys) for the former and acrylic acid (AA) for the latter. Performances of the IIPs based sensors were compared in terms of sensitivity, limits of detection (LOD), dissociation constants and selectivity. The gravimetric results indicated that both designed sensors can detect picomolar concentrations of lead ions. These values are, in fact, significantly inferior to the World Health Organization (WHO) maximum accepted limit in drinking water, and among the lowest LODs ever reported in the literature. The relevant dissociation constants, calculated from the most appropriate fits of the calibration curves, were estimated at: Kd <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> = (1.1 ± 0.4) × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-10</sup> M and Kd <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> = (1.1 ± 0.8) × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-5</sup> M for L-Cys-IIP/Pb <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> and Kd <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> = (1.1 ± 0.3) × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-13</sup> M and Kd <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> = (5.9 ± 1.8) × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-10</sup> M for AA-PPy-IIP/ Pb <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2+</sup> , thus confirming the strong binding between the designed IIPs and lead ions. Selectivity tests were investigated with mercury, cadmium, copper, zinc, and nickel divalent ions, which largely coexist with lead ions in soils, rivers, and wastewaters.
43