Journal of Veterinary Emergency and Critical Care · 2019 · 28 citations · 30 references
MedicineClinical SciencesPediatric PulmonologyPulmonary Function TestingPulmonologyAcute Respiratory Distress SyndromeBreathing SupportMechanical VentilationRespiratory DiseaseRespiratory Failure ManagementRespiratory MedicineAcute Hypoxemic Respiratory FailureAcute Respiratory Failure AssessmentArterial Blood Gas AssessmentArterial Blood Gas MonitoringArterial Blood Gas SamplingPediatric Acute Respiratory FailureRespiratory RateRespiratory Status Assessment
Abstract Objective To evaluate arterial blood gas parameters and pulmonary radiography, before and after provision of continuous positive airway pressure (CPAP) via a pediatric helmet in dogs with acute hypoxemic respiratory failure. Design Single‐center, observational study conducted from 2016 to 2017. Setting University teaching hospital. Animals Seventeen dogs presenting with clinical signs compatible with respiratory failure, confirmed by arterial blood gas analyses. Interventions For each animal arterial blood samples and thoracic radiographs were performed at arrival (T 0 ). Hypoxemic dogs (PaO 2 <80 mm Hg), without evidence of pneumothorax or pleural effusion, received CPAP ventilation via a pediatric Helmet for at least 1 hour. At the end of CPAP ventilation, a second arterial blood gas analysis was performed at room air (T 1 ). The F‐shunt was also calculated. Measurement and Main Results Respiratory rate, heart rate and rhythm, mean blood pressure, mucosal membrane color, and rectal temperature were recorded. Tolerance to the helmet was evaluated using a predetermined scoring system. Two dogs were excluded from the study for low tolerance to the helmet. In 15 of 17 dogs, a significant difference between T 0 and T 1 was noted for PaO 2 (60.84 ± 3 mm Hg vs 80.2 ± 5.5 mm Hg), P(A‐a)O 2 (52.4 ± 4.4 mm Hg vs 35.2 ± 6 mm Hg), PaO 2 /FiO 2 (289.7 ± 14.3 vs 371 ± 21), and %SO 2 (91.3 vs 98.8). In 15 of 17 dogs, the helmet was well tolerated. F‐shunt significantly decreased following provision of CPAP (37%; range, 8.4–68% vs 6%; range, −5.6–64.3%). Conclusion The use of a pediatric helmet appears to be a suitable device for delivery of CPAP in dogs with hypoxemic acute respiratory failure. The device appears to be reasonably tolerated and improved oxygenation in most dogs.
30
Continuous Positive Airway Pressure for Treatment of Postoperative Hypoxemia
Vincenzo Squadrone, Massimiliano Coha, Elisabetta Cerutti et al. · JAMA · 2005 · 669 citations
Sean Keenan, T Sinuff, Karen E. A. Burns et al. · Canadian Medical Association Journal · 2011 · 370 citations · Full text