Journal of Radiation Research · 2019 · 59 citations · 47 references
MedicineOncologyRadiation OncologyBiomedical ImagingDiagnostic ImagingTreatment PlanningBrain ImagingComputed TomographyMagnetic Resonance Image ReconstructionMagnetic Resonance ImagingMedical ImagingThree-dimensional Conformal Radiotherapy3D-conformal RadiotherapyDose-volume RelationshipGenerative Adversarial NetworksGlioblastoma ImagingImaging-based Treatment PlanningMagnetic Resonance-guided RadiotherapyVolumetric Modulated Arc Therapy DosimetryVolumetric Modulated Arc Therapy Planning
The aim of this work is to generate synthetic computed tomography (sCT) images from multi-sequence magnetic resonance (MR) images using an adversarial network and to assess the feasibility of sCT-based treatment planning for brain radiotherapy. Datasets for 15 patients with glioblastoma were selected and 580 pairs of CT and MR images were used. T1-weighted, T2-weighted and fluid-attenuated inversion recovery MR sequences were combined to create a three-channel image as input data. A conditional generative adversarial network (cGAN) was trained using image patches. The image quality was evaluated using voxel-wise mean absolute errors (MAEs) of the CT number. For the dosimetric evaluation, 3D conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) plans were generated using the original CT set and recalculated using the sCT images. The isocenter dose and dose-volume parameters were compared for 3D-CRT and VMAT plans, respectively. The equivalent path length was also compared. The mean MAEs for the whole body, soft tissue and bone region were 108.1 ± 24.0, 38.9 ± 10.7 and 366.2 ± 62.0 hounsfield unit, respectively. The dosimetric evaluation revealed no significant difference in the isocenter dose for 3D-CRT plans. The differences in the dose received by 2% of the volume (D2%), D50% and D98% relative to the prescribed dose were <1.0%. The overall equivalent path length was shorter than that for real CT by 0.6 ± 1.9 mm. A treatment planning study using generated sCT detected only small, clinically negligible differences. These findings demonstrated the feasibility of generating sCT images for MR-only radiotherapy from multi-sequence MR images using cGAN.
47
Delving Deep into Rectifiers: Surpassing Human-Level Performance on ImageNet Classification
Kaiming He, Xiangyu Zhang, Shaoqing Ren et al. · 2015 · 18.8K citations
Conditional Generative Adversarial Nets
Mehdi Mirza, Simon Osindero · arXiv (Cornell University) · 2014 · 8.9K citations · Full text
N4ITK: Improved N3 Bias Correction
Nicholas J. Tustison, Brian Avants, Philip A. Cook et al. · IEEE Transactions on Medical Imaging · 2010 · 6.4K citations
Medicine, Neuroscience, Radiology +16