Optics Express · 2019 · 36 citations · 21 references
EngineeringElectrical EngineeringInstrumentationOpticsSensorsAngular MeasurementOptical InstrumentationPolarization OpticsIntensity ModulationLight IntensityMagnetometersOptical DetectionOptical Rotation MeasurementPhase-sensitive DetectionPolarizationSpin Precession
Ne gyroscope is reported. A sinusoidal driving voltage is applied to drive the LCVR and is skillfully used to produce a high-frequency modulation for the probe light. The modulation helps to avoid electronic detection noise appearing at low frequencies and allows for phase-sensitive detection. The coefficient of rate ramp can be reduced from 1.31 (deg/h)/h to 0.05 (deg/h)/h (Allan deviation), and the bias instability of about 0.08 deg/h at the averaging time of 200 s is achieved. Therefore, the long-term stability of the angular velocity measurement can be improved and other optical modulators can be replaced to facilitate the miniaturization of the gyroscope by using this intensity modulation detection method. This optical rotation detection method also can be applied to other miniaturized atomic sensors, such as atomic magnetometers.
21
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
J. C. Allred, ROBERT LYMAN, T. W. Kornack et al. · Physical Review Letters · 2002 · 1K citations
Resonant nonlinear magneto-optical effects in atoms
Dmitry Budker, Wojciech Gawlik, Derek F. Jackson Kimball et al. · Reviews of Modern Physics · 2002 · 806 citations · Full text
Natural Sciences, Physics, Optics +13
A low-noise ferrite magnetic shield
Applied Physics Letters · 2007 · 245 citations · Full text