Experimental Validation of a Full-Size Pole Pair Set-Up of an MW-Class Direct Drive Superconducting Wind Turbine Generator

Xiaowei Song, Nenad Mijatović, Carsten Bührer, J. Kellers, J. Wiezoreck, Jens Krause, Hendrik Pütz, Jesper Hansen, Anders V. Rebsdorf

IEEE Transactions on Energy Conversion · 2019 · 31 citations · 23 references

Concepts

Abstract

The article presents a full-size pole pair set-up of an MW-class direct drive (DD) high temperature superconducting (HTS) wind turbine generator. The set-up serves as a precursor to the world's first full-scale DD HTS generator developed within the EU-funded EcoSwing project. The set-up built for de-risking employs an HTS field winding in the rotor and a conventional copper armature winding in the stator, representing a minimum independent unit of the corresponding full generator. Such a prototyping approach well reflects the performance of the full generator at a low cost. The article first explains the main design considerations of the full generator, followed by designing and construction details of the set-up. Afterward, a number of tests for determining the key performance of the set-up are reported. The testing results showed that the HTS field winding ran stably at its rated current of 480 A and was well maintained below 30 K. Moreover, the tangential force in the set-up reached 29.8 kN, projecting the 2 MW target output power of the full generator. The set-up developed effectively validated the design ideas and engineering feasibilities of the full generator, leading to successful kick-off of the EcoSwing project.

References

23