AIP conference proceedings · 2019 · 59 citations · 15 references
EngineeringCivil EngineeringMaterials EngineeringBuilding MaterialsRadiation MeasurementRadiation ShieldingConcrete ConstructionConcrete MaterialsConcrete ShieldingConcrete TechnologyGamma-ray ShieldingShielding MaterialsAttenuation Coefficient MeasurementConcrete Density EffectsConcrete Shielding MaterialsExperimental Shielding MeasurementsGrain-size ControlNarrow Beam AttenuationNarrow Beam Shielding
The mass attenuation coefficient µm measured experimentally for two different series of concretes (with different grain size and with different basalt ratios) using the narrow beam transmission method. The experimental measurements performed at gamma ray energies 662, 1173 and 1332 keV emitted by gamma ray sources 137Cs and 60Co respectively. Moreover, the half value layer of the prepared concretes was calculated. Furthermore, the dependence of the µm on the incident energy and concrete densities were studied. The studied revealed that the basalt grain size and basalt ratio make a significant variation in the µm for the prepared concrete. The µm increases with decrease the grain size while, it is increase with increase the basalt ratio in the prepared concretes.
15
M.I. Sayyed, Mengge Dong, H.O. Tekın et al. · Materials Chemistry and Physics · 2018 · 119 citations