Investigative Ophthalmology & Visual Science · 2016 · 49 citations · 48 references
Health ProfessionsBiomedical EngineeringMaterials ScienceBiomaterialsContact Lens PracticeTribologyContact Lens MaterialsLens CareSoft Contact LensesAgeingContact Lens FrictionFrictionFriction CoefficientLubricant EffectsReusable Contact LensesSilicone Hydrogel Contact LensesSilicone Hydrogel Lenses
PURPOSE: To characterize the effect of lubricant composition and in vitro ageing on the coefficient of friction (CoF) of a wide range of commercially available soft contact lenses (SCLs). METHODS: The CoF of SCLs was characterized by means of microtribometry against a mucin-coated glass disk. One reusable (RU) silicone-hydrogel (SiHy) lens, senofilcon A, and two daily disposable (DD) lenses, etafilcon A (hydrogel) and nelfilcon A (hydrogel), were tested under different lubricant solutions, including a tear-like fluid (TLF) containing proteins and lipids. Five RU (balafilcon A [SiHy], comfilcon A [SiHy], etafilcon A [hydrogel], lotrafilcon B [SiHy], senofilcon A [SiHy]) and five DD (delefilcon A [SiHy], etafilcon A [hydrogel; two lens types], narafilcon A [SiHy], nelfilcon A [hydrogel]) lenses were tested before and after exposure to an in vitro ageing process, consisting of continuous immersion and withdrawal from TLF for 18 hours. The CoF in TLF was further compared to previously published data collected in a different lubricant. RESULTS: After in vitro ageing, three RU (balafilcon A, etafilcon A, comfilcon A) and three DD (delefilcon A, etafilcon A, nelfilcon A) lenses displayed a significant increase in CoF (P < 0.05). Lenses that contained poly (vinyl pyrrolidone; PVP) showed unaltered CoF after ageing. CONCLUSIONS: An in vitro methodology to simulate in vivo wearing of contact lenses has been proposed. The results suggest that certain lens materials show increased CoF after ageing, with potential clinical implications. The results indicate that the presence of a persistent wetting agent is of advantage to maintain a low CoF after prolonged wearing.
48
Reduction of frictional forces between solid surfaces bearing polymer brushes
Jacob Klein, Eugenia Kumacheva, D. Mahalu et al. · Nature · 1994 · 609 citations
A multi‐centre study of lapsed contact lens wearers
Graeme P. Young, Jane Veys, Nicola Pritchard et al. · Ophthalmic and Physiological Optics · 2002 · 250 citations
Lyndon Jones, Noel A. Brennan, Jose Manuel González‐Méijome et al. · Investigative Ophthalmology & Visual Science · 2013 · 231 citations · Full text